Yasutoshi Shinoda1, Akira Sato2, Toru Adach3, Isao Nishi1, Akihiko Nogami3, Kazutaka Aonuma3, Masaki Ieda3. 1. Department of Cardiology, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan; Department of Internal Medicine, Kamisu Saiseikai Hospital, Kamisu, Japan. 2. Department of Cardiology, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan. Electronic address: asato@md.tsukuba.ac.jp. 3. Department of Cardiology, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan.
Abstract
BACKGROUND: An audiovisual telesupport system that enables real-time audiovisual communications between 2 long-distance hospitals is one method of telemedicine. The usefulness and safety of radiofrequency catheter ablation (RFCA) using an audiovisual telesupport system has not been well established. OBJECTIVE: The purpose of this study was to evaluate the effectiveness and safety of RFCA using an audiovisual telesupport system. METHODS: An audiovisual telesupport system using a strictly secured virtual network was established between Kamisu Saiseikai Hospital (operator with 10 years' experience and 800 procedures) and the University of Tsukuba (advisor with >20 years' experience and 8000 procedures). We evaluated 19 initial consecutive patients who underwent RFCA using this system for tachyarrhythmia: 10 with atrial fibrillation (AF), 5 with paroxysmal supraventricular tachycardia (PSVT), 3 with premature ventricular contraction (PVC), and 1 with atrial flutter. Electrophysiological and procedural characteristics were retrospectively assessed. RESULTS: Acute success was achieved in all 19 patients without any major complications, with the advisor's audiovisual assistance. Mean procedure time and fluoroscopic time were 161 ± 44 minutes and 24 ± 14 minutes for AF, 110 ± 17 minutes and 28 ± 8 minutes for PVC, and 132 ± 19 minutes and 32 ± 2 minutes for PSVT, respectively. There was no recurrence of clinical arrhythmia in 17 of the 19 patients (89%) during 13 ± 9 month follow-up. CONCLUSION: An audiovisual telesupport system for RFCA is a useful and safe method that enabled the electrophysiologist with limited human resources to make an optimal decision regarding procedural strategy and endpoint with the remote advisor's audiovisual assistance.
BACKGROUND: An audiovisual telesupport system that enables real-time audiovisual communications between 2 long-distance hospitals is one method of telemedicine. The usefulness and safety of radiofrequency catheter ablation (RFCA) using an audiovisual telesupport system has not been well established. OBJECTIVE: The purpose of this study was to evaluate the effectiveness and safety of RFCA using an audiovisual telesupport system. METHODS: An audiovisual telesupport system using a strictly secured virtual network was established between Kamisu Saiseikai Hospital (operator with 10 years' experience and 800 procedures) and the University of Tsukuba (advisor with >20 years' experience and 8000 procedures). We evaluated 19 initial consecutive patients who underwent RFCA using this system for tachyarrhythmia: 10 with atrial fibrillation (AF), 5 with paroxysmal supraventricular tachycardia (PSVT), 3 with premature ventricular contraction (PVC), and 1 with atrial flutter. Electrophysiological and procedural characteristics were retrospectively assessed. RESULTS: Acute success was achieved in all 19 patients without any major complications, with the advisor's audiovisual assistance. Mean procedure time and fluoroscopic time were 161 ± 44 minutes and 24 ± 14 minutes for AF, 110 ± 17 minutes and 28 ± 8 minutes for PVC, and 132 ± 19 minutes and 32 ± 2 minutes for PSVT, respectively. There was no recurrence of clinical arrhythmia in 17 of the 19 patients (89%) during 13 ± 9 month follow-up. CONCLUSION: An audiovisual telesupport system for RFCA is a useful and safe method that enabled the electrophysiologist with limited human resources to make an optimal decision regarding procedural strategy and endpoint with the remote advisor's audiovisual assistance.
Authors: Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yu-Feng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg Journal: Circ Arrhythm Electrophysiol Date: 2021-02-12
Authors: Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yufeng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg Journal: Cardiovasc Digit Health J Date: 2021-01-29
Authors: Niklas Beyhoff; Miry Zhu; Lukas Zanders; David M Leistner; Anthony Nobles; Mark Schroeder; Fabian Barbieri; Ulf Landmesser; Markus Reinthaler Journal: J Am Heart Assoc Date: 2022-02-08 Impact factor: 6.106
Authors: Andrzej Glowniak; Myroslav Petkanych; Katarzyna Wojewoda; Vladimir Komiaty; Marcin Sudol; Oksana Dyomenko; Kamil Torres; Andrzej Wysokinski; Antonio Sorgente; Gian-Battista Chierchia; Carlo de Asmundis Journal: Cardiol J Date: 2021-09-15 Impact factor: 2.737