Literature DB >> 32348968

Whole gamma imaging: a new concept of PET combined with Compton imaging.

Eiji Yoshida1, Hideaki Tashima, Kotaro Nagatsu, Atsushi B Tsuji, Kei Kamada, Katia Parodi, Taiga Yamaya.   

Abstract

We proposed a concept of whole gamma imaging (WGI) that utilizes all detectable gamma rays for imaging. An additional detector ring, which is used as the scatterer, is inserted in the field-of-view of a PET ring so that single gamma rays can be detected by the Compton imaging method. In particular, for the non-pure positron emitters which emit an additional gamma ray almost at the same time, triple gamma imaging will be enabled; localization on each line-of-response (LOR) is possible by using the Compton cone of the additional gamma ray. We developed a prototype to show a proof of the WGI concept. The diameters of scatterer ring and PET ring were set as 20 cm and 66 cm, respectively. For Compton imaging of the 662-keV gamma ray from a 137Cs point source, spatial resolution obtained by the list-mode OSEM algorithm was 4.4 mm FWHM at the 8 cm off-center position and 13.1 mm FWHM at the center position. For PET imaging of a 22Na point source, spatial resolution was about 2 mm FWHM at all positions. For the triple gamma imaging, 5.7 mm FWHM (center) and 4.8 mm FWHM (8 cm off-center) were obtained for the 22Na point source just by plotting the intersecting points between each LOR and each Compton cone of the 1275-keV gamma ray. No image reconstruction was applied. Scandium-44 was produced as a practical candidate of the non-pure positron emitters, and 6.6 mm FWHM (center) and 5.8 mm FWHM (8 cm off-center) were obtained in the same manner. This direct imaging approach which neither requires time-consuming event integration nor iterative image reconstruction may allow in vivo real-time tracking of a tiny amount of activity. Our initial results showed the feasibility of the WGI concept, which is a novel combination of PET and Compton imaging.

Entities:  

Year:  2020        PMID: 32348968     DOI: 10.1088/1361-6560/ab8e89

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

Review 1.  Photon counting detectors and their applications ranging from particle physics experiments to environmental radiation monitoring and medical imaging.

Authors:  Ryosuke Ota
Journal:  Radiol Phys Technol       Date:  2021-03-19

Review 2.  Compton imaging for medical applications.

Authors:  Hideaki Tashima; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2022-07-22

3.  Performance demonstration of a hybrid Compton camera with an active pinhole for wide-band X-ray and gamma-ray imaging.

Authors:  Akihisa Omata; Jun Kataoka; Kazuya Fujieda; Shogo Sato; Eri Kuriyama; Hiroki Kato; Atsushi Toyoshima; Takahiro Teramoto; Kazuhiro Ooe; Yuwei Liu; Keiko Matsunaga; Takashi Kamiya; Tadashi Watabe; Eku Shimosegawa; Jun Hatazawa
Journal:  Sci Rep       Date:  2020-08-20       Impact factor: 4.379

4.  Quantitative PET in the 2020s: a roadmap.

Authors:  Steven R Meikle; Vesna Sossi; Emilie Roncali; Simon R Cherry; Richard Banati; David Mankoff; Terry Jones; Michelle James; Julie Sutcliffe; Jinsong Ouyang; Yoann Petibon; Chao Ma; Georges El Fakhri; Suleman Surti; Joel S Karp; Ramsey D Badawi; Taiga Yamaya; Go Akamatsu; Georg Schramm; Ahmadreza Rezaei; Johan Nuyts; Roger Fulton; André Kyme; Cristina Lois; Hasan Sari; Julie Price; Ronald Boellaard; Robert Jeraj; Dale L Bailey; Enid Eslick; Kathy P Willowson; Joyita Dutta
Journal:  Phys Med Biol       Date:  2021-03-12       Impact factor: 4.174

5.  Multi-modal 3D imaging of radionuclides using multiple hybrid Compton cameras.

Authors:  Akihisa Omata; Miho Masubuchi; Nanase Koshikawa; Jun Kataoka; Hiroki Kato; Atsushi Toyoshima; Takahiro Teramoto; Kazuhiro Ooe; Yuwei Liu; Keiko Matsunaga; Takashi Kamiya; Tadashi Watabe; Eku Shimosegawa; Jun Hatazawa
Journal:  Sci Rep       Date:  2022-02-15       Impact factor: 4.996

Review 6.  Development and Applications of Compton Camera-A Review.

Authors:  Raj Kumar Parajuli; Makoto Sakai; Ramila Parajuli; Mutsumi Tashiro
Journal:  Sensors (Basel)       Date:  2022-09-28       Impact factor: 3.847

Review 7.  Roadmap: proton therapy physics and biology.

Authors:  Harald Paganetti; Chris Beltran; Stefan Both; Lei Dong; Jacob Flanz; Keith Furutani; Clemens Grassberger; David R Grosshans; Antje-Christin Knopf; Johannes A Langendijk; Hakan Nystrom; Katia Parodi; Bas W Raaymakers; Christian Richter; Gabriel O Sawakuchi; Marco Schippers; Simona F Shaitelman; B K Kevin Teo; Jan Unkelbach; Patrick Wohlfahrt; Tony Lomax
Journal:  Phys Med Biol       Date:  2021-02-26       Impact factor: 4.174

8.  Positron annihilation localization by nanoscale magnetization.

Authors:  Yaser H Gholami; Hushan Yuan; Moses Q Wilks; Lee Josephson; Georges El Fakhri; Marc D Normandin; Zdenka Kuncic
Journal:  Sci Rep       Date:  2020-11-20       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.