| Literature DB >> 32346816 |
J Jason Lundy1, Stephen Joel Coons2, Emuella Flood3, Mira J Patel4.
Abstract
INTRODUCTION: While the EQ-5D-5L has been migrated to several electronic modes, evidence supporting the measurement equivalence of the original paper-based instrument to the electronic modes is limited.Entities:
Mesh:
Year: 2020 PMID: 32346816 PMCID: PMC7340667 DOI: 10.1007/s40271-020-00419-6
Source DB: PubMed Journal: Patient ISSN: 1178-1653 Impact factor: 3.883
Fig. 1Equivalence study scheme used in the four crossover comparisons independent sample
Demographic characteristics
| Characteristics | Paper test–retest ( | Paper–handheld–web ( | Paper–handheld–tablet ( | Paper–web–IVR ( | Handheld–tablet–web ( |
|---|---|---|---|---|---|
| Sex | |||||
| Male | 21 (35) | 27 (45) | 31 (51.67) | 13 (21.3) | 25 (58.33) |
| Female | 39 (65) | 33 (55) | 29 (48.33) | 48 (78.7) | 35 (41.67) |
| Age | 46.3 ± 15.1 (21–86) | 46.5 ± 12.6 (20–79) | 43.9 ± 14.0 (22–82) | 49.9 ± 15.8 (18–77) | 38.2 ± 13.6 (18–72) |
| Education | |||||
| Left school with no qualifications | 1 (1.67) | 1 (1.67) | 1 (1.67) | 2 (3.3) | 1 (1.67) |
| GCSE or equivalent | 9 (15.0) | 7 (11.67) | 2 (3.33) | 8 (13.1) | 7 (11.67) |
| A level or equivalent | 7 (11.67) | 9 (15.0) | 6 (10.0) | 8 (13.1) | 10 (16.67) |
| College/technical college | 9 (15.0) | 14 (23.33) | 7 (11.67) | 11 (18.0) | 9 (15.0) |
| University: undergraduate level | 25 (41.67) | 21 (35.0) | 25 (41.67) | 20 (32.8) | 19 (31.67) |
| University: postgraduate level | 9 (15.0) | 8 (13.33) | 19 (31.67) | 12 (19.7) | 14 (23.33) |
| Ethnic group | |||||
| African | – | 1 (1.67) | – | 2 (3.3) | 2 (3.33) |
| Asian/Asian British | 1 (1.67) | 2 (3.33) | 4 (6.67) | 5 (8.2) | 1 (1.67) |
| Bangladeshi | 2 (3.33) | 1 (1.67) | 3 (5.0) | – | 1 (1.67) |
| Black/African/Caribbean/Black British | 9 (15.0) | 4 (6.67) | 5 (8.33) | – | 6 (10.0) |
| Caribbean | – | – | 1 (1.67) | – | 2 (3.33) |
| Chinese | – | 1 (1.67) | – | – | – |
| English/Welsh/Scottish/Northern Irish/British | 38 (63.33) | 32 (53.33) | 22 (36.67) | 53 (86.9) | 26 (43.33) |
| Indian | 4 (6.67) | 3 (5.0) | 2 (3.33) | – | 1 (1.67) |
| Irish | – | 1 (1.67) | – | 1 (1.6) | 1 (1.67) |
| Mixed/multiple ethnic groups | 2 (3.33) | 3 (5.0) | 6 (10.0) | – | 5 (8.33) |
| Other | 3 (5.0) | 7 (11.67) | 17 (28.33) | – | 9 (15.0) |
| Pakistani | – | 1 (1.67) | – | – | 2 (3.33) |
| White and Asian | 1 (1.67) | – | – | – | 1 (1.67) |
| White and Black African | – | 2 (3.33) | – | – | 3 (5.0) |
| White and Black Caribbean | – | 2 (3.33) | – | – | – |
Data are presented as mean ± standard deviation (range) or N (%) unless otherwise indicated
GCSE general certificate of secondary education, IVR interactive voice response
Paper test–retest kappa and weighted kappa
| Domain | Kappa | Weighted kappa |
|---|---|---|
| Mobility | 0.661 (0.131) | 0.888 (0.072) |
| Self-care | 0.766 (0.163) | 0.538 (0.356) |
| Usual activities | 0.740 (0.100) | 0.882 (0.142) |
| Pain/discomfort | 0.819 (0.070) | 0.909 (0.138) |
| Anxiety/depression | 0.834 (0.071) | 0.927 (0.098) |
Figures in parentheses represent standard errors
Paper test–retest mean differences and intraclass correlation coefficients
| Variable | Mean ± SD | Mean difference (95% CI) | ICC (95% CI) |
|---|---|---|---|
| Index: time 1 | 0.860 ± 0.155 | 0.003 (− 0.011 to 0.017) | 0.946 (0.911–0.967) |
| Index: time 2 | 0.857 ± 0.168 | ||
| EQ VAS: time 1 | 81.550 ± 16.384 | − 0.800 (− 1.927 to 0.327) | 0.964 (0.940–0.978) |
| EQ VAS: time 2 | 82.350 ± 16.275 |
CI confidence interval, EQ VAS EuroQoL visual analog scale, ICC intraclass correlation coefficient, SD standard deviation
Paper–handheld–web mean differences and intraclass correlation coefficients
| Variable | Mean difference (95% CI) | Mode × order interaction | ICC (95% CI) |
|---|---|---|---|
| Index: paper–handheld | 0.004 (− 0.009 to 0.017) | 0.952 (0.921–0.971) | |
| Index: paper–web | 0.006 (− 0.006 to 0.019) | 0.964 (0.941–0.978) | |
| Index: handheld–web | 0.003 (− 0.008 to 0.014) | 0.970 (0.950–0.982) | |
| EQ VAS: paper–handheld | 0.050 (− 0.694 to 0.794) | 0.985 (0.975–0.991) | |
| EQ VAS: paper–web | 0.117 (− 0.248 to 0.482) | 0.996 (0.993–0.997) | |
| EQ VAS: handheld–web | 0.067 (− 0.528 to 0.661) | 0.991 (0.984–0.994) |
CI confidence interval, ICC intraclass correlation coefficient
Paper–handheld–tablet mean differences and intraclass correlation coefficients
| Variable | Mean difference (95% CI) | Mode × order interaction | ICC (95% CI) |
|---|---|---|---|
| Index: paper–handheld | 0.001 (− 0.002 to 0.005) | 0.996 (0.993–0.997) | |
| Index: paper–tablet | − 0.004 (− 0.009 to 0.002) | 0.989 (0.981–0.993) | |
| Index: handheld–tablet | − 0.005 (− 0.011 to 0.001) | 0.983 (0.972–0.990) | |
| EQ VAS: paper–handheld | 0.807 (0.144 to 1.471) | 0.987 (0.977–0.992) | |
| EQ VAS: paper–tablet | 0.189 (− 0.592 to 0.970) | 0.984 (0.973–0.990) | |
| EQ VAS: handheld–tablet | − 0.619 (− 1.478 to 0.241) | 0.980 (0.967–0.988) |
CI confidence interval, ICC intraclass correlation coefficient
Paper–web–interactive voice response mean differences and intraclass correlation coefficients
| Variable | Mean difference (95% CI) | Mode × order interaction | ICC (95% CI) |
|---|---|---|---|
| Index: paper–IVR | − 0.005 (− 0.015 to 0.005) | 0.989 (0.981–0.993) | |
| Index: paper–web | − 0.001 (− 0.012 to 0.009) | 0.990 (0.983–0.994) | |
| Index: web–IVR | − 0.004 (− 0.017 to 0.010) | 0.982 (0.969–0.989) | |
| EQ VAS: paper–IVR | 0.067 (− 0.392 to 0.526) | 0.997 (0.994–0.998) | |
| EQ VAS: paper–web | − 0.059 (− 0.434 to 0.316) | 0.998 (0.996–0.999) | |
| EQ VAS: web–IVR | 0.126 (− 0.408 to 0.661) | 0.996 (0.993–0.997) |
CI confidence interval, ICC intraclass correlation coefficient, IVR interactive voice response
Handheld–tablet–web mean differences and intraclass correlation coefficients
| Variable | Mean difference (95% CI) | Mode × order interaction | ICC (95% CI) |
|---|---|---|---|
| Index: handheld–tablet | 0.000 (− 0.006 to 0.006) | 0.990 (0.983–0.994) | |
| Index: handheld–web | 0.000 (− 0.010 to 0.009) | 0.972 (0.953–0.983) | |
| Index: tablet–web | 0.000 (− 0.011 to 0.010) | 0.966 (0.943–0.979) | |
| EQ VAS: handheld–tablet | − 0.393 (− 0.735 to − 0.051) | 0.995 (0.990–0.997) | |
| EQ VAS: handheld–web | − 0.031 (− 0.800 to 0.737) | 0.971 (0.952–0.983) | |
| EQ VAS: tablet–web | 0.361 (− 0.305 to 1.027) | 0.978 (0.963–0.987) |
CI confidence interval, ICC intraclass correlation coefficient
| The EQ-5D-5L has been migrated to several electronic modes of data collection. This study aimed to determine the measurement equivalence of the original paper-based instrument versus all available electronic modes. |
| This study comprehensively examined the equivalence of the EQ-5D-5L on all available electronic modes (i.e., handheld, tablet, interactive voice response, and web). |
| The comparisons of the paper format and the screen-based and phone-based formats of the EQ-5D-5L provided substantial evidence supporting the measurement equivalence of these modes of data collection. |