Literature DB >> 32342674

Glove-Wall System for Respiratory Specimen Collection and COVID-19 Mass Screening.

Bo Kyung Koo1,2, Ji Hwan Bang1,3, Sun Young Kim4, Eun Jin Kim4, Sang Won Park1,3,5.   

Abstract

Entities:  

Year:  2020        PMID: 32342674      PMCID: PMC7335641          DOI: 10.3947/ic.2020.52.2.219

Source DB:  PubMed          Journal:  Infect Chemother        ISSN: 1598-8112


× No keyword cloud information.
Dear Editor: In response to the coronavirus disease 2019 (COVID-19) pandemic, Korea has devised an effective strategy for massive diagnostic testing combined with isolation [123]. Specimen collection for COVID-19 requires heavy personal protective equipment (PPE) which is exhausting for the examiner and difficult during mass screening. Therefore, we implemented the ‘Glove-Wall system' at a screening clinic since 10th February 2020 first reported ever in the literature. The Glove-Wall is composed of a translucent plate window with a pair of sleeved gloves (Fig. 1A). A physician determines the patient eligibility according to the COVID-19 criteria. Respiratory specimen is collected from the suspected patient in the Glove-Wall area where the examiner and examinee are completely separated (Fig. 1B). The examiner needs minimum PPE and does not need to change PPE between patients; therefore, the wait time is minimal. Specimen containers dropped into a collection box are sent to a laboratory as a batch after each session.
Figure 1

Glove-Wall system in a COVID-19 screening clinic.

(A) Collection of respiratory specimen for a COVID-19 test using Glove-Wall: The Glove-Wall completely separates the examinee and examiner. (B) The layout of a COVID-19 screening clinic in Boramae Medical Center. The physician room is separated from the examination room. (C) Surface disinfection and cleaning with alcohol and quaternary ammonium wipes. (D) Use of single-use gloves that are worn over the fixed sleeved gloves. Informed consent was obtained from the individuals in the image for the publication of this report.

To secure the safety of the examinees side and prevent cross-contamination from the surrounding environment, the examiner disinfects the fixed gloves between patients using alcohol and quaternary ammonium wipes approved for coronavirus (Fig. 1C) [4]. Each examinee is instructed to perform hand hygiene with alcohol products before and after exit. After each session, the entire room is cleaned and disinfected with diluted sodium hypochlorite [4]. The fixed gloves are regularly replaced. Single use gloves are worn over the fixed sleeved thin gloves for every procedure (Fig. 1D). To prevent airborne transmission from previous candidates and allow rapid air change, the examinee's space is designed to be small (2.5 m x 1.3 m x 2.5 m) with a volume of 8.1 m3 and a 1 m x 2 m sized door leading to open air. For effective ventilation and filtration, a portable negative pressure machine is installed with an airflow rate at 530 m3/h and 65 air changes per hour that removes 99% of airborne contaminants in 5 minutes [56]. The ventilation safety is secured during the 5-minute interval between patients. About 1,000 diagnostic procedures were performed in a 5 week-period, and any procedure-related healthcare worker infection was not reported. The application may be flexible in different situations. Multiple units will be needed to handle large-scale testing. Additionally, the examinee's space can be modified as needed, for example, open air system can be adopted in warm climates. In summary, the Glove-Wall system for respiratory specimen collection has improved examiner's safety, minimum PPE requirement, and limited examinee's safety.
  4 in total

1.  Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care settings, 2005.

Authors:  Paul A Jensen; Lauren A Lambert; Michael F Iademarco; Renee Ridzon
Journal:  MMWR Recomm Rep       Date:  2005-12-30

2.  Clinical Characteristics of Coronavirus Disease 2019 in China.

Authors:  Wei-Jie Guan; Zheng-Yi Ni; Yu Hu; Wen-Hua Liang; Chun-Quan Ou; Jian-Xing He; Lei Liu; Hong Shan; Chun-Liang Lei; David S C Hui; Bin Du; Lan-Juan Li; Guang Zeng; Kwok-Yung Yuen; Ru-Chong Chen; Chun-Li Tang; Tao Wang; Ping-Yan Chen; Jie Xiang; Shi-Yue Li; Jin-Lin Wang; Zi-Jing Liang; Yi-Xiang Peng; Li Wei; Yong Liu; Ya-Hua Hu; Peng Peng; Jian-Ming Wang; Ji-Yang Liu; Zhong Chen; Gang Li; Zhi-Jian Zheng; Shao-Qin Qiu; Jie Luo; Chang-Jiang Ye; Shao-Yong Zhu; Nan-Shan Zhong
Journal:  N Engl J Med       Date:  2020-02-28       Impact factor: 91.245

3.  Early dynamics of transmission and control of COVID-19: a mathematical modelling study.

Authors:  Adam J Kucharski; Timothy W Russell; Charlie Diamond; Yang Liu; John Edmunds; Sebastian Funk; Rosalind M Eggo
Journal:  Lancet Infect Dis       Date:  2020-03-11       Impact factor: 25.071

4.  Report on the Epidemiological Features of Coronavirus Disease 2019 (COVID-19) Outbreak in the Republic of Korea from January 19 to March 2, 2020.

Authors: 
Journal:  J Korean Med Sci       Date:  2020-03-16       Impact factor: 2.153

  4 in total
  2 in total

Review 1.  Personal Protective Equipment for Healthcare Workers during the COVID-19 Pandemic.

Authors:  Sun Hee Park
Journal:  Infect Chemother       Date:  2020-06

Review 2.  Age-Related Morbidity and Mortality among Patients with COVID-19.

Authors:  Seung Ji Kang; Sook In Jung
Journal:  Infect Chemother       Date:  2020-06-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.