Literature DB >> 32338472

Influence of implant scanbody material and operator on scanning fluency and polygonal mesh numbers of digital impression: an in vitro study.

A Nardi1, A Barlattani2, L Arcuri3, F Lio4, A Papa5.   

Abstract

The purpose of this study is to evaluate the influence of implant scanbody (ISB) material and operator on scanning fluency and polygonal mesh numbers of a confocal microscopy intraoral scanning (IOS). An edentulous maxillary master model with 6 implant analogues was assembled. Thereafter 3 ISBs featured with same geometry but different materials (polyetheretherketone (PK), titanium (T) and PK with a titanium base (PKT)) were produce and scanned according to a randomized sequence by three different operators. The confocal microscopy IOS resulted in 45 STL test files that were processed to a dedicate software to obtain the request data. The overall analysis of fluency (imm/sec) showed the following results: mean 11.997 imm/sec, SD 2.355. The multivariate analysis showed statistical significance of material (p<.0001) and operator (p<.0001) influence. The univariate analysis referred to polygonal mesh numbers expressed the following results: mean 30327.8, SD 2432.5. The multivariate analysis stressed how there is a related effect to materials (p<.0001) and operator (p=0.0205). PKT represented the material with the best results for both. Analyzing the overall distribution histogram for scanning fluency, the IOS device seems to work with higher frequency at level of 13 imm/sec. The distribution of the measurements in the reference histograms showed an effect related to both variables referring to scanning fluency as well as to polygonal mesh numbers. Operator can be considered as a random effect; regarding the materials, the difference between PKT and PK can be related to the different base material. The dissimilar optical properties of T justify the different behavior. Copyright 2020 Biolife Sas. www.biolifesas.org.

Entities:  

Keywords:  digital impression; implant scanbody; intraoral scanner; polygonal mesh; scanning fluency

Mesh:

Substances:

Year:  2019        PMID: 32338472

Source DB:  PubMed          Journal:  J Biol Regul Homeost Agents        ISSN: 0393-974X            Impact factor:   1.711


  1 in total

1.  Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study.

Authors:  Bowen Ma; Xinxin Yue; Yujie Sun; Lingyan Peng; Wei Geng
Journal:  BMC Oral Health       Date:  2021-12-10       Impact factor: 2.757

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.