| Literature DB >> 32336823 |
Claudio Carvalho Dalavia1, Suzan Menasce Goldman1, Homero José de Farias E Melo1, Claudio Elias Kater1, Jacob Szejnfeld1, Wagner Iared1, Sergio Aron Ajzen1.
Abstract
OBJECTIVE: To investigate the advantages of using modified signal intensity measurements on chemical shift imaging alone or in conjunction with proton magnetic resonance spectroscopy in the differential diagnosis of adrenal adenomas.Entities:
Keywords: Adenoma/diagnostic imaging; Adrenal gland neoplasms; Adrenal glands; Magnetic resonance imaging/methods; Proton magnetic resonance spectroscopy/methods
Year: 2020 PMID: 32336823 PMCID: PMC7170587 DOI: 10.1590/0100-3984.2019.0095
Source DB: PubMed Journal: Radiol Bras ISSN: 0100-3984
Physical parameters used in order to acquire MRI sequences in a 1.5-T scanner.
| Sequence | Number of images | Thickness (mm) | TR (ms) | TE (ms) | Matrix | FOV (mm) |
|---|---|---|---|---|---|---|
| T2-weighted | ||||||
| Axial HASTE | 24 | 3.0 | 1000-2000 | 87 | 167 × 256 | 280-350 |
| Axial fat saturation HASTE | 24 | 3.0 | 1000-2000 | 87 | 167 × 256 | 280-350 |
| Coronal HASTE | 20 | 3.0 | 1000-2000 | 82 | 167 × 256 | 280-350 |
| Sagittal H.ASTE | 13 | 3.0 | 1000-2000 | 87 | 167 × 256 | 280-350 |
| Tl-weighted | ||||||
| Axial in-phase chemical shift | 24 | 3.0 | 173 | 4.8 | 167 × 256 | 280-350 |
| Axial out-of-phase chemical shift | 24 | 3.0 | 173 | 2.4 | 167 × 256 | 280-350 |
| Axial gadolinium-enhanced VIBE | 70 | 1.0 | 5.45 | 2.58 | 179 × 256 | 280-350 |
FOV, field of view; VIBE, volumetric interpolated breath-hold examination.
Figure 1Chemical shift MRI. Placement of the ROI to cover one half to two thirds of the adrenal mass: axial out-of-phase (A,C,E) and in-phase (B,D,F) sequences.
Figure 2Spectroscopy graphs of four adrenal masses: adenoma (A), metastasis (B), pheochromocytoma (C), and carcinoma (D). The peaks of Cho, Cr, Lip, Glx, Lac, and H2O are shown in their respective curves. Red arrows indicate adrenal nodules in the different axes. Adapted from Melo et al.(.
Figure 3Study flow diagram.
Results of the measurements of SII and metabolite ratios in adenomas and nonadenomas.
| Variable | Adenomas (n = 69) | Nonadenomas (n = 28) | |||||
|---|---|---|---|---|---|---|---|
| Mean ± standard deviation | Minimum | Maximum | Mean ± standard deviation | Minimum | Maximum | ||
| Sll | |||||||
| Minimum | 68.3 ± 28.2 | -55.4 | 96.9 | 15.4 ± 41.4 | -63.5 | 86.2 | |
| Mean | 54.3 ± 26.7 | -34.5 | 100.0 | 15.7 ± 26.9 | -16.2 | 70.4 | |
| Maximum | 41.9 ± 26.7 | -48.1 | 100.0 | 14.5 ± 26.1 | -11.5 | 100.0 | |
| Metabolite ratios | |||||||
| Lac./Cr | 2.14 ± 1.68 | 0.00 | 7.34 | -6.05 ± 7.37 | -21.90 | 2.74 | |
| Glx/Cr | -5.06 ± 7.55 | -33.83 | 1.73 | 0.48 ± 4.12 | -11.29 | 7.65 | |
| Cho/Cr | 0.92 ± 0.36 | 0.00 | 1.50 | 1.43 ± 0.43 | 0.96 | 2.36 | |
| 4.0-4.3 ppm/Cr | 0.96 ± 0.79 | 0.00 | 3.50 | 5.26 ± 7.33 | 0.98 | 4.74 | |
| Lip/Cr | 27.7 ± 22.701 | 2.56 | 101.06 | 51.80 ± 80.91 | 32.85 | 363.77 | |
| Cho/Lip | 0.11 ± 0.14 | 0.00 | 0.67 | 0.20 ± 0.27 | 0.02 | 1.14 | |
Cutoff points of each SII value and metabolite ratio for differentiating adenomas from nonadenomas.
| Variable | Cutoff point | Sensitivity (%) | Specificity (%) | Positive predictive value (%) | Negative predictive value (%) | Accuracy | |
|---|---|---|---|---|---|---|---|
| Sll | |||||||
| Minimum | 38.3 | 91.3 | 75.0 | 90.0 | 77.8 | 86.6 | < 0.0001 |
| Mean | 25.7 | 88.4 | 75.0 | 89.7 | 72.4 | 84.5 | < 0.0001 |
| Maximum | 10.9 | 88.4 | 67.9 | 87.1 | 70.4 | 82.5 | < 0.0001 |
| Metabolite ratios | |||||||
| Lac/Cr | -0.52 | 82.4 | 100 | 100 | 93.62 | 95.09 | < 0.0001 |
| Glx/Cr | 0.17 | 94.1 | 90.9 | 80.01 | 97.55 | 91.79 | < 0.0001 |
| Cho/Cr | 1.06 | 88.2 | 65.9 | 50.02 | 93.52 | 72.12 | < 0.0001 |
| 4.0-4.3 ppm/Cr | 1.60 | 88.2 | 86.4 | 71.51 | 94.98 | 86.90 | < 0.0001 |
| Lip/Cr | 28.14 | 64.7 | 68.2 | 44.05 | 83.31 | 67.22 | 0.135 |
| Cho/Lip | 0.08 | 70.6 | 63.6 | 42.87 | 84.83 | 65.55 | 0.037 |
Cutoff points of each SII value for the differentiation between adenomas and nonadenomas, by nodule size (diameter).
| Nodule diameter | Number of cases | Cutoff point | Sensitivity | Specificity | Positive predictive value | Negative predictive value | Accuracy |
|---|---|---|---|---|---|---|---|
| ≤ 2.0 cm | |||||||
| Sll-minimum | 35 | 38.3 | 96.4 | 42.9 | 87.1 | 75.0 | 85.7 |
| Sll-mean | 35 | 25.7 | 96.4 | 28.6 | 84.4 | 66.7 | 82.9 |
| Sll-maximum | 35 | 10.9 | 96.4 | 28.6 | 84.4 | 66.7 | 82.9 |
| 2.1-4.0 cm | |||||||
| Sll-minimum | 37 | 38.3 | 93.8 | 60.0 | 93.8 | 60.0 | 89.2 |
| Sll-mean | 37 | 25.7 | 90.6 | 80.0 | 96.7 | 57.1 | 89.2 |
| Sll-maximum | 37 | 10.9 | 93.7 | 60.0 | 93.7 | 60.0 | 89.2 |
| > 4.0 cm | |||||||
| Sll-minimum | 25 | 38.3 | 66.7 | 81.3 | 66.7 | 81.3 | 76.0 |
| Sll-mean | 25 | 25.7 | 66.7 | 87.5 | 75.0 | 82.4 | 80.0 |
| Sll-maximum | 25 | 10.9 | 55.6 | 81.3 | 62.5 | 76.5 | 72.0 |