Literature DB >> 32335056

Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial.

Christina Leydolt1, Daniel Schartmüller1, Luca Schwarzenbacher1, Veronika Röggla1, Sabine Schriefl1, Rupert Menapace2.   

Abstract

PURPOSE: To compare the incidence and intensity of posterior capsule opacification (PCO) and neodymium-yttrium-aluminum-garnet (Nd:YAG) capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) that differ in the proprietary material characteristics and design features, over a period of 3 years.
DESIGN: Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison.
METHODS: Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. PATIENT POPULATION: Eighty patients (160 eyes) had bilateral cataract surgery and received a Vivinex XY1 IOL in 1 eye and an AcrySof SN60WF IOL in the other eye. OBSERVATION PROCEDURES: Follow-up examinations were performed 3 years after surgery. Digital retroillumination images were taken of each eye. The amount of PCO (score: 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software (AQUA). MAIN OUTCOME MEASURE: PCO score (scale, 0-10).
RESULTS: The mean objective PCO score of the Vivinex XY1 IOLs was 0.9 ± 0.8 compared to the PCO score of 1.4 ± 1.1 for the AcrySof SN60WF IOLs (P < .001). Three years postoperatively, 11.4% of patients had an Nd:YAG capsulotomy in the Vivinex XY1 eye and 18.6% had a capsulotomy in the AcrySof SN60WF eye (P = .23).
CONCLUSION: The new hydrophobic acrylic Vivinex XY1 IOL showed significantly lower PCO rates and lower YAG rates compared to the AcrySof SN60WF IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge plays a key role in PCO development.
Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32335056     DOI: 10.1016/j.ajo.2020.04.011

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  4 in total

1.  Visually Disturbing Vitreous Floaters following Neodymium-Doped Yttrium Aluminum Garnet Capsulotomy: A Single-Center Case Series.

Authors:  Ha Eun Sim; Seung Hwa Baik; Je-Hyung Hwang
Journal:  Case Rep Ophthalmol       Date:  2022-06-28

2.  GSH Levels Serve As a Biological Redox Switch Regulating Sulforaphane-Induced Cell Fate in Human Lens Cells.

Authors:  Thao Phuong Ngoc Huynh; Richard P Bowater; Federico Bernuzzi; Shikha Saha; I Michael Wormstone
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-12-01       Impact factor: 4.799

3.  Two-dimensional ultrathin Ti3C2 MXene nanosheets coated intraocular lens for synergistic photothermal and NIR-controllable rapamycin releasing therapy against posterior capsule opacification.

Authors:  Zi Ye; Yang Huang; Jinglan Li; Tianju Ma; Lixiong Gao; Huihui Hu; Qing He; Haiying Jin; Zhaohui Li
Journal:  Front Bioeng Biotechnol       Date:  2022-08-30

4.  Accuracy of the Barrett Universal II formula integrated into a commercially available optical biometer when using a preloaded single-piece intraocular lens.

Authors:  Hiroki Mieno; Osamu Hieda; Toshihide Ikeda; Shino Hayashi; Masatsugu Hashida; Kimiaki Urabe; Chie Sotozono
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.