Honggui Lin1, Feixiang Fang2, Jiahui Zang2, Jianlong Su2, Qingyuan Tian1,3, Ranjith Kumar Kankala2, Xuexia Lin2.
Abstract
In this study, a convenient assay method has been developed based on labeled functional nucleic acids (H-DNA) and a competitive fluorescent lateral flow immunoassay (CF-LFI) for ampicillin (AMP) detection. Herein, we designed the tunable AMP probes for AMP detection based on the AMP aptamer, and the secondary DNA fragment. The probes can generate tunable signals on the test line (T line) and control line (C line) according to the concentration of AMP. The accuracy of detection was improved by optimizing the tunable AMP probes. Under the optimal conditions, the linear concentration of AMP detection is ranged from 10 to 200 ng/L with a limit of quantitation (LOQ) value of 2.71 ng/L, and the recovery is higher than 80.5 %. Moreover, the developed method shows the potential application for AMP detection in the hospital wastewater.Entities:
Keywords: CF-LFI; ampicillin; hospital wastewater; oligonucleotide probe
Year: 2020 PMID: 32326021 PMCID: PMC7231327 DOI: 10.3390/mi11040431
Source DB: PubMed Journal: Micromachines (Basel) ISSN: 2072-666X Impact factor: 2.891
Figure 1Schematic of CF-LFI for AMP detection.
Figure 2Evaluation of probes (H-DNA, T-DNA, C-DNA) for AMP detection.
Figure 3Optimization of DNA conditions. (A) FL intensity against various concentrations of C-DNA and T-DNA, and (B) various ratios of H-DNA 1 and T-DNA or C-DNA 1.
Figure 4Optimization of the detection time. (A) Image of AMP detection time. (B) FL intensity of different detection time at T line.
Cross-reaction of some antibiotics with H-DNA 1, T-DNA and C-DNA 1 in the proposed CF-LFI system.
| H-DNA 1, T-DNA and C-DNA 1 | Average of Cross- Reactivity (%) (n = 3) | RSD (%) (n = 3) |
|---|---|---|
| AMP | 100 | 5.67 |
| PG | 7.40 | 3.56 |
| KA | 5.53 | 3.89 |
| OTC | 0.88 | 2.76 |
| TC | 0.67 | 2.34 |
| CTC | 6.60 | 4.34 |
Figure 5(A) Image of the selectivity of the proposal. (B) FLT/C indicates the FL intensity ratio of the T-line/C-line. (C) Image of the intensity corresponding AMP concentrations. (D) The FL intensity ratio was between T-line and C-line with different AMP concentrations. Inset shows a linear range from 10 to 200 ng/L. FLT/C indicates the FL intensity ratio of T-line/C-line.
The AMP detection from hospital wastewaters by the developed method.
| Sample No. | Detection [AMP] (ng/L) | Spiked [AMP] (ng/L) | Recovery (%) | RSD (%) | Five Dilute Sample with Spiked [AMP] (ng/L) | Recovery (%) | RSD (%) | Ten Dilute Sample with Spiked [AMP] (ng/L) | Recovery (%) | RSD (%) |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | - | 20 | 104.2 | 9.39 | 150 | 104.3 | 9.67 | 150 | 100.5 | 9.27 |
| 2 | - | 20 | 94.6 | 10.57 | 150 | 88.7 | 7.34 | 150 | 86.8 | 6.57 |
| 3 | - | 20 | 86.1 | 8.43 | 150 | 89.6 | 7.76 | 150 | 92.4 | 7.12 |
| 4 | - | 20 | 97.5 | 7.56 | 150 | 87.2 | 8.43 | 150 | 86.7 | 8.03 |
| 5 | - | 20 | 82.7 | 9.81 | 150 | 89.7 | 9.34 | 150 | 99.7 | 8.96 |
| 6 | - | 20 | 85.9 | 6.01 | 150 | 90.1 | 9.43 | 150 | 87.8 | 9.65 |
| 7 | - | 20 | 103.1 | 5.01 | 150 | 103.4 | 4.52 | 150 | 105.6 | 3.01 |
| 8 | - | 20 | 88.4 | 4.67 | 150 | 98.7 | 3.01 | 150 | 91.3 | 3.08 |
| 9 | - | 20 | 99.4 | 3.82 | 150 | 91.5 | 7.63 | 150 | 92.8 | 6.37 |
| 10 | - | 20 | 89.8 | 4.69 | 150 | 90.5 | 5.64 | 150 | 90.5 | 4.99 |