Literature DB >> 32324543

Non-Negative Iterative Convex Refinement Approach for Accurate and Robust Reconstruction in Cerenkov Luminescence Tomography.

Meishan Cai, Zeyu Zhang, Xiaojing Shi, Junying Yang, Zhenhua Hu, Jie Tian.   

Abstract

Cerenkov luminescence tomography (CLT) is a promising imaging tool for obtaining three-dimensional (3D) non-invasive visualization of the in vivo distribution of radiopharmaceuticals. However, the reconstruction performance remains unsatisfactory for biomedical applications because the inverse problem of CLT is severely ill-conditioned and intractable. In this study, therefore, a novel non-negative iterative convex refinement (NNICR) approach was utilized to improve the CLT reconstruction accuracy, robustness as well as the shape recovery capability. The spike and slab prior information was employed to capture the sparsity of Cerenkov source, which could be formalized as a non-convex optimization problem. The NNICR approach solved this non-convex problem by refining the solutions of the convex sub-problems. To evaluate the performance of the NNICR approach, numerical simulations and in vivo tumor-bearing mice models experiments were conducted. Conjugated gradient based Tikhonov regularization approach (CG-Tikhonov), fast iterative shrinkage-thresholding algorithm based Lasso approach (Fista-Lasso) and Elastic-Net regularization approach were used for the comparison of the reconstruction performance. The results of these experiments demonstrated that the NNICR approach obtained superior reconstruction performance in terms of location accuracy, shape recovery capability, robustness and in vivo practicability. It was believed that this study would facilitate the preclinical and clinical applications of CLT in the future.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32324543     DOI: 10.1109/TMI.2020.2987640

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  Sensitivity improved Cerenkov luminescence endoscopy using optimal system parameters.

Authors:  Xueli Chen; Xinyu Wang; Xiangfeng Meng; Tianyu Yan; Yun Zheng; Honghao Cao; Feng Ren; Xu Cao; Xiaojian Lu; Shuhui Liang; Kaichun Wu
Journal:  Quant Imaging Med Surg       Date:  2022-01

2.  Attention mechanism-based locally connected network for accurate and stable reconstruction in Cerenkov luminescence tomography.

Authors:  Xiaoning Zhang; Meishan Cai; Lishuang Guo; Zeyu Zhang; Biluo Shen; Xiaojun Zhang; Zhenhua Hu; Jie Tian
Journal:  Biomed Opt Express       Date:  2021-11-18       Impact factor: 3.732

3.  Noninvasive multimodal fluorescence and magnetic resonance imaging of whole-organ intervertebral discs.

Authors:  Wuwei Ren; Shangbin Cui; Mauro Alini; Sibylle Grad; Quanyu Zhou; Zhen Li; Daniel Razansky
Journal:  Biomed Opt Express       Date:  2021-05-07       Impact factor: 3.732

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.