Survival of Short and Ultra-Short Locking-Taper Implants Supporting Single Crowns in the Posterior Mandible: A 3-Year Retrospective Study.

Giorgio Lombardo1, Annarita Signoriello1, Miguel Simancas-Pallares2, Mauro Marincola3, Pier Francesco Nocini1.   

Abstract

The purpose of this retrospective study was to determine survival and peri-implant marginal bone loss of short and ultra-short implants placed in the posterior mandible. A total of 98 patients received 201 locking-taper implants between January 2014 and January 2015. Implants were placed with a 2-stage approach and restored with single crowns. Clinical and radiographic examinations were performed at 3-year recall appointments. At that time, the proportion of implant survival by length, and variations of crestal bone levels (mean crestal bone loss and mean apical shift of the "first bone-to-implant contact point" position) were assessed. Significance level was set at 0.05. The total number of implants examined 36 months after loading included: 71 implants, 8.0 mm in length; 82 implants, 6.0 mm in length; and 48 implants, 5.0 mm in length. Five implants failed. The overall proportion of survival was 97.51%, with 98.59% for the 8.0-mm implants, 97.56% for the 6.0-mm implants, and 95.83% for the 5.0-mm implants. No statistically significant differences were found among the groups regarding implant survival (P = .73), mean crestal bone loss (P = .31), or mean apical shift of the "first bone-to-implant contact point" position (P = .36). Single-crown short and ultra-short implants may offer predictable outcomes in the atrophic posterior mandibular regions, though further investigations with longer follow-up evaluations are necessary to validate our results.

Entities:  

Keywords:  zzm321990 zzm321990 bone losszzm321990 zzm321990 ; zzm321990 zzm321990 mandiblezzm321990 zzm321990 ; zzm321990 zzm321990 short implantzzm321990 zzm321990 ; zzm321990 zzm321990 single crownzzm321990 zzm321990 ; zzm321990 zzm321990 survivalzzm321990 zzm321990 ; zzm321990 zzm321990 ultra-short implantzzm321990 zzm321990

Mesh:

Substances:

Year:  2020        PMID: 32315035     DOI: 10.1563/aaid-joi-D-19-00190

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  5 in total

1.  Antiresorptive therapy and dental implant survival: an up to 20-year retrospective cohort study in women.

Authors:  Yu-Chi Cheng; Rolf Ewers; Katherine Morgan; Muneki Hirayama; Laura Murcko; John Morgan; Edmara T P Bergamo; Estevam A Bonfante
Journal:  Clin Oral Investig       Date:  2022-08-24       Impact factor: 3.606

2.  The application of locking-taper implants in posterior area implant restoration with insufficient occlusal-gingival distances.

Authors:  Guoxi Sun; Lei Cao; Haiying Zhang
Journal:  Am J Transl Res       Date:  2021-06-15       Impact factor: 4.060

3.  Single-Crown, Short and Ultra-Short Implants, in Association with Simultaneous Internal Sinus Lift in the Atrophic Posterior Maxilla: A Three-Year Retrospective Study.

Authors:  Giorgio Lombardo; Mauro Marincola; Annarita Signoriello; Giovanni Corrocher; Pier Francesco Nocini
Journal:  Materials (Basel)       Date:  2020-05-11       Impact factor: 3.623

4.  Survival rates of ultra-short (<6 mm) compared with short locking-taper implants supporting single crowns in posterior areas: A 5-year retrospective study.

Authors:  Giorgio Lombardo; Annarita Signoriello; Mauro Marincola; Pietro Liboni; Estevam A Bonfante; Pier F Nocini
Journal:  Clin Implant Dent Relat Res       Date:  2021-11-18       Impact factor: 4.259

5.  Short and ultra-short (<6-mm) locking-taper implants supporting single crowns in posterior areas (part II): A 5-year retrospective study on periodontally healthy patients and patients with a history of periodontitis.

Authors:  Giorgio Lombardo; Annarita Signoriello; Alessia Pardo; Xiomara Zilena Serpa Romero; Luis Armando Vila Sierra; Luisa Arévalo Tovar; Mauro Marincola; Pier Francesco Nocini
Journal:  Clin Implant Dent Relat Res       Date:  2022-05-30       Impact factor: 4.259