Fibreoptic tracheal intubation in COVID-19: not so fast.

Craig Lyons1.   

Abstract

Entities:  

Keywords:  COVID-19; airway management; apnoeic oxygenation; high-flow nasal oxygen; tracheal intubation

Mesh:

Year:  2020        PMID: 32312573      PMCID: PMC7151494          DOI: 10.1016/j.bja.2020.04.005

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


× No keyword cloud information.
Editor—Wu and colleagues recently described the use of high-flow nasal oxygen (HFNO) during fibreoptic tracheal intubation in critically ill patients with coronavirus disease 2019 (COVID-19). This study was undertaken on the premise that fibreoptic tracheal intubation reduces the risk of virus transmission to the healthcare worker compared with laryngoscopy. The authors stated that they used fibreoptic bronchoscopy to ‘reduce tracheal intubation-induced coughing and subsequent spread of virus’. However, the use of a neuromuscular blocking agent (used for all patients) eliminates coughing and increases the likelihood of intubation success with laryngoscopy. Furthermore, the authors stated that HFNO use is ‘not associated with an increase in air or surface contamination’ based on a recent study in critically ill patients with bacterial pneumonia. However, whilst this study demonstrated no greater risk of contamination with HFNO when compared with a control group using oxygen mask, contamination was indeed detected in both groups. In the study by Wu and colleagues, there was no use of an oxygen mask in the control arm during the apnoea period, whilst use of HFNO persisted in the intervention arm. Therefore, we cannot conclude, based on their evidence, that HFNO does not cause greater aerosolisation. The degree of aerosolisation that is necessary to create a significant risk of COVID-19 infection to the clinician is perhaps the more relevant question, and this remains unknown. The fact that the six anaesthesiologists who undertook the study are ‘currently not infected’ is a positive observation, but is not an indicator of safety; this is a small number, and the rate of infection by any method of intubation is not known to be as high as 1:6 with adequate personal protective equipment. The primary endpoint of ‘intubation time’ was defined as the period from the beginning of bronchoscopy until proper tracheal tube placement was confirmed. The intubation time was 7 s shorter in the HFNO arm vs face-mask arm. Whilst reaching statistical significance, this is arguably clinically insignificant. The higher minimum Spo 2 of 94% vs 91% during tracheal intubation with HFNO vs standard mask oxygenation is also clinically insignificant, particularly given that there was no difference between both groups in the incidence of Spo 2 <80% during intubation. The time period between the onset of apnoea and the verification of tracheal tube position is a more classical measure of the time it takes to intubate a patient, as this best represents the period where the patient is depleting their preoxygenation reserves. This period was 60 s longer than the ‘intubation time’ quoted, as the anaesthesiologists first waited 60 s to enable a dose of rocuronium 1 mg kg−1 to take effect. Based on the figures supplied, it took an estimated 2 min and 20 s from the onset of apnoea to intubate 75% of the patients. As tracheal intubation via laryngoscopy would likely not have taken this long, this represents an unnecessarily long duration of exposure. Furthermore, the authors expressed a desire to avoid bag-mask ventilation as it intensifies viral spread. However, in taking longer to secure the airway, the likelihood of oxygen desaturation was increased, which may then paradoxically require bag-mask ventilation. Bag-mask ventilation is more likely to be avoided by performing laryngoscopy in the first instance. Whilst fibreoptic intubation may allow the anaesthetist to stand a greater distance away from the airway, optimal technique involves holding the controller vertically above the airway, limiting the distance achieved from the patient. Additionally, there is greater contact with the airway as the scope is typically stabilised with the hand over the nose or mouth—areas that can have a significant viral load. The authors do not state whether they performed nasal or oral fibreoptic intubations. This is of relevance when HFNO is being used as a nasal route of tube passage greatly limits oxygen insufflation through the nare used for the bronchoscope. The merits of using HFNO during the preoxygenation phase of the study, as seen in this RCT, are questionable. A recent study has indicated that face-mask preoxygenation is superior to HFNO preoxygenation, likely because a tight-fitting face mask prevents entrainment of room air, and implies that any benefit from HFNO arises with apnoeic oxygenation alone. For anaesthetists attempting this technique, the benefits of both a face mask and HFNO can be harnessed by using a face mask alone for preoxygenation followed by HFNO insufflation during the apnoeic period. , The authors concluded that HFNO ‘provided a shorter intubation time and less frequent incidence of desaturation during attempts at fibreoptic tracheal intubation compared with preoxygenation by face-mask ventilation’. Irrespective of the superiority of one method over another, neither of these has been compared with the standard of care of rapid sequence intubation, and both may represent inferior alternatives.

Declaration of interest

The author declares that they have no conflicts of interest.
  6 in total

Review 1.  Uses and mechanisms of apnoeic oxygenation: a narrative review.

Authors:  C Lyons; M Callaghan
Journal:  Anaesthesia       Date:  2019-02-19       Impact factor: 6.955

2.  Effects of avoidance or use of neuromuscular blocking agents on outcomes in tracheal intubation: a Cochrane systematic review.

Authors:  L H Lundstrøm; C H V Duez; A K Nørskov; C V Rosenstock; J L Thomsen; A M Møller; S Strande; J Wetterslev
Journal:  Br J Anaesth       Date:  2018-04-04       Impact factor: 9.166

Review 3.  High-flow nasal oxygen therapy in intensive care and anaesthesia.

Authors:  T Renda; A Corrado; G Iskandar; G Pelaia; K Abdalla; P Navalesi
Journal:  Br J Anaesth       Date:  2017-11-21       Impact factor: 9.166

4.  Comparison of high-flow nasal cannula versus oxygen face mask for environmental bacterial contamination in critically ill pneumonia patients: a randomized controlled crossover trial.

Authors:  C C H Leung; G M Joynt; C D Gomersall; W T Wong; A Lee; L Ling; P K S Chan; P C W Lui; P C Y Tsoi; C M Ling; M Hui
Journal:  J Hosp Infect       Date:  2018-10-15       Impact factor: 3.926

5.  High-flow nasal oxygen vs. standard flow-rate facemask pre-oxygenation in pregnant patients: a randomised physiological study.

Authors:  W Shippam; R Preston; J Douglas; J Taylor; A Albert; A Chau
Journal:  Anaesthesia       Date:  2019-01-20       Impact factor: 6.955

6.  High-flow nasal-oxygenation-assisted fibreoptic tracheal intubation in critically ill patients with COVID-19 pneumonia: a prospective randomised controlled trial.

Authors:  Cai-Neng Wu; Lin-Zhi Xia; Kun-Hong Li; Wu-Hua Ma; Dong-Nan Yu; Bo Qu; Bi-Xi Li; Ying Cao
Journal:  Br J Anaesth       Date:  2020-03-20       Impact factor: 9.166

  6 in total
  1 in total

Review 1.  Safety of Healthcare Workers During the Airway Management in Adult and Pediatric Patients with COVID-19.

Authors:  Farzad Rahmani; Ata Mahmoodpoor; Shiva Salmasi; Haniyeh Ebrahimi Bakhtavar
Journal:  Anesth Pain Med       Date:  2021-05-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.