Literature DB >> 32309058

Feasibility of Early Meal Detection Based on Abdominal Sound.

Konstanze Kolle1,2, Anders Lyngvi Fougner1, Reinold Ellingsen3, Sven Magnus Carlsen2,4, Oyvind Stavdahl1.   

Abstract

In classical approaches for an artificial pancreas, continuous glucose monitoring (CGM) is the only measured variable used for insulin dosing and additional control functions. The CGM values are subject to time delays and slow dynamics between blood and the sensing location. These time lags compromise the controller's performance in maintaining (near to) normal glucose levels. Meal information could enhance the control outcome. However, meal announcement by the user is not reliable, and it takes 30 min to 40 min from meal onset until a meal is detected by methods based on CGM. In this pilot study, the use of bowel sounds for meal detection was investigated. In particular, we focused on whether bowel sounds change qualitatively during or shortly after meal ingestion. After fasting for at least 4 h, 11 healthy volunteers ingested a lunch meal at their usual time. Abdominal sound was recorded by a condenser microphone that was attached to the right upper quadrant of the abdomen by medical tape. Features that describe the power distribution over the frequency spectrum were extracted and used for classification by support vector machines. These classifiers were trained in a leave-one-out cross-validation scheme. Meals could be detected on average 10 min (std: 4.4 min) after they had started. Half of these were detected without false alarms. This shows that abdominal sound monitoring could provide an early meal detection. Further studies should investigate this possibility on a larger population in more general settings.

Entities:  

Keywords:  Abdominal sound; artificial pancreas; bowel sounds; meal detection; pattern recognition

Year:  2019        PMID: 32309058      PMCID: PMC6824555          DOI: 10.1109/JTEHM.2019.2940218

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  2 in total

1.  Development of a bowel sound detector adapted to demonstrate the effect of food intake.

Authors:  Ning Wang; Alison Testa; Barry J Marshall
Journal:  Biomed Eng Online       Date:  2022-01-04       Impact factor: 2.819

Review 2.  Automated Bowel Sound Analysis: An Overview.

Authors:  Jan Krzysztof Nowak; Robert Nowak; Kacper Radzikowski; Ireneusz Grulkowski; Jaroslaw Walkowiak
Journal:  Sensors (Basel)       Date:  2021-08-05       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.