Literature DB >> 32306768

Acute Effects of Transcatheter Aortic Valve Replacement on Central Aortic Hemodynamics in Patients With Severe Aortic Stenosis.

Michael Michail1,2, Alun D Hughes2, Andrea Comella1, James N Cameron3, Robert P Gooley1, Liam M McCormick1, Anthony Mathur2,4, Kim H Parker5, Adam J Brown1, James D Cameron1.   

Abstract

Severe aortic stenosis induces abnormalities in central aortic pressure, with consequent impaired organ and tissue perfusion. Relief of aortic stenosis by transcatheter aortic valve replacement (TAVR) is associated with both a short- and long-term hypertensive response. Counterintuitively, patients who are long-term normotensive post-TAVR have a worsened prognosis compared with patients with hypertension, yet the underlying mechanisms are not understood. We investigated immediate changes in invasively measured left ventricular and central aortic pressure post-TAVR in patients with severe aortic stenosis using aortic reservoir pressure, wave intensity analysis, and indices of aortic function. Fifty-four patients (mean age 83.6±6.2 years, 50.0% female) undergoing TAVR were included. We performed reservoir pressure and wave intensity analysis on invasively acquired pressure waveforms from the ascending aorta and left ventricle immediately pre- and post-TAVR. Following TAVR, there were increases in systolic, diastolic, mean, and pulse aortic pressures (all P<0.05). Post-TAVR reservoir pressure was unchanged (54.5±12.4 versus 56.6±14.0 mm Hg, P=0.30) whereas excess pressure increased 47% (29.0±10.9 versus 42.6±15.5 mm Hg, P<0.001). Wave intensity analysis (arbitrary units, au) demonstrated increased forward compression wave (64.9±35.5 versus 124.4±58.9, ×103 au, P<0.001), backward compression wave (11.6±5.5 versus 14.4±6.9, ×103 au, P=0.01) and forward expansion wave energies (43.2±27.3 versus 82.8±53.1, ×103 au, P<0.001). Subendocardial viability ratio improved with aortic function effectively unchanged post-TAVR. Increased central aortic pressure following TAVR relates to increased transmitted power and energy to the proximal aorta with increased excess pressure but unchanged reservoir pressure. These changes provide a potential mechanism for the improved prognosis associated with relative hypertension post-TAVR.

Entities:  

Keywords:  blood pressure; perfusion; prognosis; stenosis; transcatheter aortic valve replacement

Mesh:

Year:  2020        PMID: 32306768      PMCID: PMC7224985          DOI: 10.1161/HYPERTENSIONAHA.119.14385

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  20 in total

1.  Arterial reservoir-excess pressure and ventricular work.

Authors:  Kim H Parker; Jordi Alastruey; Guy-Bart Stan
Journal:  Med Biol Eng Comput       Date:  2012-02-26       Impact factor: 2.602

2.  Systemic vascular load in calcific degenerative aortic valve stenosis: insight from percutaneous valve replacement.

Authors:  Raquel Yotti; Javier Bermejo; Enrique Gutiérrez-Ibañes; Candelas Pérez del Villar; Teresa Mombiela; Jaime Elízaga; Yolanda Benito; Ana González-Mansilla; Alicia Barrio; Daniel Rodríguez-Pérez; Pablo Martínez-Legazpi; Francisco Fernández-Avilés
Journal:  J Am Coll Cardiol       Date:  2015-02-10       Impact factor: 24.094

3.  Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.

Authors:  Brian R Lindman; Catherine M Otto; Pamela S Douglas; Rebecca T Hahn; Sammy Elmariah; Neil J Weissman; William J Stewart; Girma M Ayele; Feifan Zhang; Alan Zajarias; Hersh S Maniar; Hasan Jilaihawi; Eugene Blackstone; Khaja M Chinnakondepalli; E Murat Tuzcu; Martin B Leon; Philippe Pibarot
Journal:  Circ Cardiovasc Imaging       Date:  2017-07       Impact factor: 7.792

4.  Compression and expansion wavefront travel in canine ascending aortic flow: wave intensity analysis.

Authors:  Christopher J H Jones; Motoaki Sugawara; Yukiyoshi Kondoh; Keisuke Uchida; Kim H Parker
Journal:  Heart Vessels       Date:  2002-03       Impact factor: 2.037

5.  Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure.

Authors:  Aram V Chobanian; George L Bakris; Henry R Black; William C Cushman; Lee A Green; Joseph L Izzo; Daniel W Jones; Barry J Materson; Suzanne Oparil; Jackson T Wright; Edward J Roccella
Journal:  Hypertension       Date:  2003-12-01       Impact factor: 10.190

6.  Separation of the reservoir and wave pressure and velocity from measurements at an arbitrary location in arteries.

Authors:  J Aguado-Sierra; J Alastruey; J-J Wang; N Hadjiloizou; J Davies; K H Parker
Journal:  Proc Inst Mech Eng H       Date:  2008-05       Impact factor: 1.617

7.  Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.

Authors:  Martin B Leon; Craig R Smith; Michael J Mack; Raj R Makkar; Lars G Svensson; Susheel K Kodali; Vinod H Thourani; E Murat Tuzcu; D Craig Miller; Howard C Herrmann; Darshan Doshi; David J Cohen; Augusto D Pichard; Samir Kapadia; Todd Dewey; Vasilis Babaliaros; Wilson Y Szeto; Mathew R Williams; Dean Kereiakes; Alan Zajarias; Kevin L Greason; Brian K Whisenant; Robert W Hodson; Jeffrey W Moses; Alfredo Trento; David L Brown; William F Fearon; Philippe Pibarot; Rebecca T Hahn; Wael A Jaber; William N Anderson; Maria C Alu; John G Webb
Journal:  N Engl J Med       Date:  2016-04-02       Impact factor: 91.245

Review 8.  Pathophysiological coronary and microcirculatory flow alterations in aortic stenosis.

Authors:  Michael Michail; Justin E Davies; James D Cameron; Kim H Parker; Adam J Brown
Journal:  Nat Rev Cardiol       Date:  2018-07       Impact factor: 32.419

9.  Rapid Pacing-Induced Right Ventricular Dysfunction Is Evident After Balloon-Expandable Transfemoral Aortic Valve Replacement.

Authors:  Richard G Axell; Paul A White; Joel P Giblett; Lynne Williams; Bushra S Rana; Andrew Klein; Michael O'Sullivan; William R Davies; Cameron G Densem; Stephen P Hoole
Journal:  J Am Coll Cardiol       Date:  2017-02-21       Impact factor: 24.094

10.  The arterial reservoir pressure increases with aging and is the major determinant of the aortic augmentation index.

Authors:  Justin E Davies; John Baksi; Darrel P Francis; Nearchos Hadjiloizou; Zachary I Whinnett; Charlotte H Manisty; Jazmin Aguado-Sierra; Rodney A Foale; Iqbal S Malik; John V Tyberg; Kim H Parker; Jamil Mayet; Alun D Hughes
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-12-11       Impact factor: 4.733

View more
  2 in total

1.  Acute Kidney Injury Following Transcatheter Aortic Valve Implantation: Association with Contrast Media Dosage and Contrast Media Based Risk Predication Models.

Authors:  Doron Sudarsky; Yarden Drutin; Fabio Kusniec; Liza Grosman-Rimon; Ala Lubovich; Wadia Kinany; Evgeni Hazanov; Michael Gelbstein; Edo Y Birati; Ibrahim Marai
Journal:  J Clin Med       Date:  2022-02-23       Impact factor: 4.241

2.  Immediate reduction in left ventricular ejection time following TAVI is associated with improved quality of life.

Authors:  Jimmy Schenk; Eline Kho; Santino Rellum; Joris Kromhout; Alexander P J Vlaar; Jan Baan; Martijn S van Mourik; Harald T Jorstad; Björn J P van der Ster; Berend E Westerhof; Steffen Bruns; Rogier V Immink; Marije M Vis; Denise P Veelo
Journal:  Front Cardiovasc Med       Date:  2022-09-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.