USB multiplex analyzer employing screen-printed silver electrodes on paper substrate; A developed design for dissolution testing.

Ali M Yehia1, Ahmed S Saad2, Mahmoud A Tantawy3.   

Abstract

Multiplex ion analyzers have been introduced recently for the assay of several inorganic ions, whilst electrochemists have extensively employed screen printed sensors for pharmaceutical analyses. This work aims to develop a USB pluggable sensor with a user-friendly design for multiplex analysis of oppositely charged co-formulated organic ions. The miniaturized screen-printed electrode was developed using silver ink on paper substrate. A compact sensor design was attained by including three electrodes, a single reference electrode along with an indicator electrode for each of the determined ions. Optimized PVC membranes were drop-casted over each of the indicator electrodes for the determination of phenylephrine HCl (PHE) and ibuprofen (IBU). The proposed multiplex potentiometric sensors exhibit Nernstian slopes of 59.2 ± 0.26 and -56.8 ± 0.16 mV/decade for PHE and IBU, respectively, with respective detection limits of 1.6 × 10-7 and 6.53 × 10-8 mol L-1. The fast and stable response of the developed sensor enabled the real-time monitoring of the combined dosage form dissolution. The dissolution profiles obtained by this potentiometric analyzer and an off-line separation technique were compared favourably, albeit our proposed in-line sensor reduced waste and time of analysis. The developed method successfully complies with the most demanding stipulations of green analytical chemistry.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dissolution test; In-line sensor; Miniaturized electrode; Multiplex ion detection; USB sensor

Year:  2020        PMID: 32305738     DOI: 10.1016/j.jpba.2020.113272

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  3 in total

1.  Portable solid-state sensor for therapeutic monitoring of an antineoplastic drug; vinblastine in human plasma.

Authors:  Maha Mohammed Galal; Ahmed Sayed Saad
Journal:  RSC Adv       Date:  2020-11-24       Impact factor: 4.036

2.  All solid-state miniaturized potentiometric sensors for flunitrazepam determination in beverages.

Authors:  Mahmoud A Tantawy; Ekram H Mohamed; Ali M Yehia
Journal:  Mikrochim Acta       Date:  2021-05-19       Impact factor: 5.833

3.  Stability indicating potentiometric method for the determination of palonosetron HCl using two different sensors.

Authors:  Mahmoud A Tantawy; Dalia A Elshabasy; Nadia F Youssef; Sawsan M Amer
Journal:  Sci Rep       Date:  2022-07-28       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.