Literature DB >> 32302205

Bioabsorbable Versus Titanium Screws in Anterior Cruciate Ligament Reconstruction Using Hamstring Autograft: A Prospective, Randomized Controlled Trial With 13-Year Follow-up.

Keran Sundaraj1, Lucy J Salmon1, Emma L Heath1, Carl S Winalski2, Ceylan Colak2, Amit Vasanji3, Justin P Roe1, Leo A Pinczewski1,4.   

Abstract

BACKGROUND: Bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been a popular choice, with theoretical advantages in imaging and surgery. Titanium and poly-L-lactic acid with hydroxyapatite (PLLA-HA) screws have been compared, but with less than a decade of follow-up. PURPOSE/HYPOTHESIS: The purpose was to compare long-term outcomes of hamstring autograft ACLR using either PLLA-HA screws or titanium screws. We hypothesized there would be no difference at 13 years in clinical scores or tunnel widening between PLLA-HA and titanium screw types, along with high-grade resorption and ossification of PLLA-HA screws. STUDY
DESIGN: Randomized controlled trial; Level of evidence, 1.
METHODS: Forty patients undergoing ACLR were randomized to receive either a PLLA-HA screw or a titanium screw for ACL hamstring autograft fixation. Blinded evaluation was performed at 2, 5, and 13 years using the International Knee Documentation Committee score, Lysholm knee score, and KT-1000 arthrometer. Magnetic resonance imaging (MRI) was performed at 2 or 5 years and 13 years to evaluate tunnel volumes, ossification around the screw, graft integration, and cyst formation. Computed tomography (CT) of patients with PLLA-HA was performed at 13 years to evaluate tunnel volumes and intratunnel ossification.
RESULTS: No differences were seen in clinical outcomes at 2, 5, or 13 years between the 2 groups. At 13 years, tibial tunnel volumes were smaller for the PLLA-HA group (2.17 cm3) compared with the titanium group (3.33 cm3; P = .004). By 13 years, the PLLA-HA group had complete or nearly complete resorption on MRI or CT scan.
CONCLUSION: Equivalent clinical results were found between PLLA-HA and titanium groups at 2, 5, and 13 years. Although PLLA-HA screws had complete or nearly complete resorption by 13 years, tunnel volumes remained largely unchanged, with minimal ossification.

Entities:  

Keywords:  ACL; bioabsorbable; bioresorbable; computed tomography; fixation; knee

Mesh:

Substances:

Year:  2020        PMID: 32302205     DOI: 10.1177/0363546520911024

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  6 in total

1.  Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation.

Authors:  Janosch Häberli; Maximilian Heilgemeir; Sebastian Valet; Ameet Aiyangar; Tom Overes; Philipp Henle; Stefan Eggli
Journal:  Arch Orthop Trauma Surg       Date:  2021-08-30       Impact factor: 2.928

Review 2.  Comparison of Bioabsorbable and Metallic Interference Screws for Graft Fixation During ACL Reconstruction: A Meta-analysis of Randomized Controlled Trials.

Authors:  Baoyun Xu; Yuling Yin; Yanling Zhu; Yu Yin; Weili Fu
Journal:  Orthop J Sports Med       Date:  2021-08-18

3.  Computed Tomography Imaging of BioComposite Interference Screw After ACL Reconstruction With Bone-Patellar Tendon-Bone Graft.

Authors:  Brian Scrivens; Melissa A Kluczynski; Marc S Fineberg; Leslie J Bisson
Journal:  Orthop J Sports Med       Date:  2021-05-06

Review 4.  A Systematic Review of Randomized Controlled Trials in Anterior Cruciate Ligament Reconstruction: Standard Techniques Are Comparable (299 Trials With 25,816 Patients).

Authors:  Hosam E Matar; Simon R Platt; Benjamin V Bloch; Peter J James; Hugh U Cameron
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-05-14

5.  The Effect of PCL Addition on 3D-Printable PLA/HA Composite Filaments for the Treatment of Bone Defects.

Authors:  Elin Åkerlund; Anna Diez-Escudero; Ana Grzeszczak; Cecilia Persson
Journal:  Polymers (Basel)       Date:  2022-08-13       Impact factor: 4.967

6.  Ultrasound-Assisted Endoscopic Removal of Pretibial Cysts Related to Biointerference Screw Degradation.

Authors:  Eirik Solheim; Eivind Inderhaug
Journal:  Arthrosc Tech       Date:  2021-04-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.