Literature DB >> 32297099

Tissue Doppler velocities for ruling out rejection in heart transplant recipients in the context of myocardial strain imaging: a multivariate, prospective, single-center study.

Martín Ruiz Ortiz1, Sara Rodríguez Diego2, Mónica Delgado Ortega2, José J Sánchez Fernández2, Rosa Ortega Salas3, Lucía Carnero Montoro2, Francisco Carrasco Ávalos2, José López Aguilera2, Amador López Granados2, José M Arizón Del Prado2, Elías Romo Peñas2, Nick Paredes Hurtado2, Jesús Oneto Fernández2, Manuel Pan2, Dolores Mesa Rubio2.   

Abstract

To investigate the value of tissue Doppler velocities for ruling out treatment-requiring acute cellular rejection (TR-ACR), in the context of myocardial deformation analysis performed by means of speckle tracking echocardiography. We performed serial echocardiograms in 37 heart transplant recipients in their first year post-transplantation within 3 h of the routine surveillance endomyocardial biopsies (EMB). The association of the sum of lateral mitral annulus systolic (s') and early diastolic (e') velocities, in absolute values, measured by tissue Doppler echocardiography (s'+ e'), with TR-ACR (ACR grade ≥ 2R) was investigated by multivariate analysis, including classic echocardiographic parameters and myocardial deformation variables. A total of 251 pairs of EMB and echo exams were performed, 35 (14%) with rejection grade ≥ 2R (TR-ACR). s' + e' was independently associated to TR-ACR (OR 0.80, 95%CI 0.72-0.89, p < 0.0005), with a C statistic of 0.79 (95%CI 0.71-0.87, p < 0.0005) by ROC curve analysis. An  s'+ e' value ≥ 23 cm/s, present in 43% of studies, had a negative predictive value of 98% for ruling out TR-ACR. Moreover, in the same patients, s'+ e' significantly decreased when TR-ACR occurred after a study without this condition (- 3.7 ± 3.3 cm/s, p = 0.003), but it was similar when rejection status was the same in the present versus the previous study. A drop in s'+ e' value < 2.7 cm/s from the previous echocardiogram, had a 99% negative predictive value for ruling out TR-ACR. Tissue Doppler velocities, a widely available echo parameter, were found to be a valuable marker for ruling out TR-ACR in this multivariate study which included myocardial deformation variables.

Entities:  

Keywords:  Rejection; Strain; Tissue doppler echocardiography; Transplantation

Year:  2020        PMID: 32297099     DOI: 10.1007/s10554-020-01843-3

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  2 in total

1.  The Role of Left Atrial Longitudinal Strain in the Diagnosis of Acute Cellular Rejection in Heart Transplant Recipients.

Authors:  Sara Rodríguez-Diego; Martín Ruiz-Ortiz; Mónica Delgado-Ortega; Jiwon Kim; Jonathan W Weinsaft; José J Sánchez-Fernández; Rosa Ortega-Salas; Lucía Carnero-Montoro; Francisco Carrasco-Ávalos; José López-Aguilera; Amador López-Granados; José M Arizón Del Prado; Elías Romo-Peñas; Laura Pardo-González; Francisco J Hidalgo-Lesmes; Manuel Pan Álvarez-Ossorio; Dolores Mesa-Rubio
Journal:  J Clin Med       Date:  2022-08-25       Impact factor: 4.964

2.  C-Reactive protein level and left ventricular mass are associated with acute cellular rejection after heart transplant.

Authors:  Débora Cestari Bacal; Miguel Morita Fernandes-Silva; Sandrigo Mangini; Marcia Santos de Jesus; Fernando Bacal
Journal:  Clinics (Sao Paulo)       Date:  2021-12-06       Impact factor: 2.365

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.