Literature DB >> 32295060

Quantifying Physical Thrombus Characteristics on Cardiovascular Biomaterials Using MicroCT.

Avi Gupta1, Claire M Johnston1, Monica T Hinds1, Deirdre E J Anderson1.   

Abstract

Hemocompatibility is a critical consideration when designing cardiovascular devices. Methods of assessing hemocompatibility range from in vitro protein adsorption and static platelet attachment to in vivo implantation. A standard preclinical assessment of biomaterial hemocompatibility is ex vivo quantification of thrombosis in a chronic arteriovenous shunt. This technique utilizes flowing blood and quantifies platelet accumulation and fibrin deposition. However, the physical parameters of the thrombus have remained unknown. This study presents the development of a novel method to quantify the 3D physical properties of the thrombus on different biomaterials: expanded polytetrafluoroethylene and a preclinical hydrogel, poly(vinyl alcohol). Tubes of 4-5 mm inner diameter were exposed to non-anticoagulated blood flow for 1 hour and fixed. Due to differences in biomaterial water absorption properties, unique methods, requiring either the thrombus or the lumen to be radiopaque, were developed to quantify average thrombus volume within a graft. The samples were imaged using X-ray microcomputed tomography (microCT). The methodologies were strongly and significantly correlated to caliper-measured graft dimensions (R2 = 0.994, p < 0.0001). The physical characteristics of the thrombi were well correlated to platelet and fibrin deposition. MicroCT scanning and advanced image analyses were successfully applied to quantitatively measure 3D physical parameters of thrombi on cardiovascular biomaterials under flow.

Entities:  

Keywords:  arteriovenous shunt; biomaterials; fibrin; hemocompatibility; microCT; platelets; thrombus; vascular graft

Year:  2020        PMID: 32295060     DOI: 10.3390/mps3020029

Source DB:  PubMed          Journal:  Methods Protoc        ISSN: 2409-9279


  2 in total

1.  Fucoidan functionalization on poly(vinyl alcohol) hydrogels for improved endothelialization and hemocompatibility.

Authors:  Yuan Yao; Aung Moe Zaw; Deirdre E J Anderson; Monica T Hinds; Evelyn K F Yim
Journal:  Biomaterials       Date:  2020-04-01       Impact factor: 12.479

2.  Hemocompatibility of micropatterned biomaterial surfaces is dependent on topographical feature size.

Authors:  Meghan E Fallon; Hillary H Le; Novella M Bates; Yuan Yao; Evelyn K F Yim; Monica T Hinds; Deirdre E J Anderson
Journal:  Front Physiol       Date:  2022-09-19       Impact factor: 4.755

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.