Literature DB >> 32291976

[Effectiveness comparison of low-temperature bone cement perfusion before and after improvement in percutaneous vertebroplasty].

Yang Zhang1, Hao Long1, Jie Xiao1, Wei Zou1, Changjun Zhou1, Jie Liu1, Guoxian Wang1.   

Abstract

OBJECTIVE: To discuss the safety and effectiveness of the improved technique by comparing the effects of low temperature bone cement infusion before and after the improvement in the percutaneous vertebroplasty (PVP).
METHODS: The clinical data of 170 patients (184 vertebrae) with osteoporotic vertebral compression fracture who met the selection criteria between January 2016 and January 2018 were retrospectively analyzed. All patients were treated with PVP by low-temperature bone cement perfusion technology. According to the technical improvement or not, the patients were divided into two groups: the group before the technical improvement (group A, 95 cases) and the group after the technical improvement (group B, 75 cases). In group A, the patients were treated by keeping the temperature of bone cement at 0℃ and parallel puncture; in group B, the patients were treated by increasing the temperature of bone cement or reducing the time of bone cement in ice salt water and cross puncture. There was no significant difference in gender, age, disease duration, T value of bone mineral density, operative segment, and preoperative vertebral compression rate, visual analogue scale (VAS) score between the two groups ( P>0.05). CT examination was performed immediately after operation, and the leakage rate of bone cement was calculated. The amount of bone cement perfusion and the proportion of bone cement in contact with the upper and lower endplates at the same time were compared between the two groups. The vertebral compression rate was calculated and the VAS score was used to evaluate the pain before operation, at immediate after operation, and last follow-up.
RESULTS: There was no complication such as incision infection, spinal nerve injury, or pulmonary embolism in both groups. There was no significant difference in the amount of bone cement perfusion between groups A and B ( t=0.175, P=0.861). There were 38 vertebral bodies (36.89%) in group A and 49 vertebral bodies (60.49%) in group B exposed to bone cement contacting with the upper and lower endplates at the same time, showing significant difference ( χ 2=10.132, P=0.001). Bone cement leakage occurred in 19 vertebral bodies (18.45%) in group A and 6 vertebral bodies (7.41%) in group B, also showing significant difference ( χ 2=4.706, P=0.030). The patients in group A and group B were followed up (13.3±1.2) months and (11.5±1.1) months, respectively. The vertebral compression rates of the two groups at immediate after operation were significantly lower than those before operation ( P<0.05), but the vertebral compression rate of group A at last follow-up was significantly higher than that at immediate after operation ( P<0.05), and there was no significant difference in group B between at immediate after operation and at last follow-up ( P>0.05). The VAS scores of the two groups at immediate after operation were significantly lower than those before operation ( P<0.05); but the VAS scores of group A at last follow-up were significantly higher than those at immediate after operation ( P<0.05) and there was no siginificant difference in group B ( P>0.05). There was no significant difference in VAS scores between the two groups at immediate after operation ( t=0.380, P=0.705); but at last follow-up, VAS score in group B was significantly lower than that in group A ( t=3.627, P=0.000).
CONCLUSION: The improved advanced low-temperature bone cement perfusion technology during PVP by increasing the viscosity of bone cement combined with cross-puncture technology, can reduce bone cement leakage, improve the distribution of bone cement in the vertebral body, and reduce the risk of vertebral collapse, and achieve better effectiveness.

Entities:  

Keywords:  Percutaneous vertebroplasty; bone cement leakage; low-temperature cement perfusion; osteoporotic vertebral compression fracture

Mesh:

Substances:

Year:  2020        PMID: 32291976      PMCID: PMC8171513          DOI: 10.7507/1002-1892.201905013

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  16 in total

1.  Effect of mixing method and storage temperature of cement constituents on the fatigue and porosity of acrylic bone cement.

Authors:  G Lewis
Journal:  J Biomed Mater Res       Date:  1999

2.  Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures.

Authors:  J S Yeom; W J Kim; W S Choy; C K Lee; B S Chang; J W Kang
Journal:  J Bone Joint Surg Br       Date:  2003-01

3.  High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage.

Authors:  Gamal Baroud; Meghan Crookshank; Marc Bohner
Journal:  Spine (Phila Pa 1976)       Date:  2006-10-15       Impact factor: 3.468

4.  Percutaneous vertebroplasty and bone cement leakage: clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures.

Authors:  Giovanni Carlo Anselmetti; Gregg Zoarski; Antonio Manca; Salvatore Masala; Haris Eminefendic; Filippo Russo; Daniele Regge
Journal:  Cardiovasc Intervent Radiol       Date:  2008-04-04       Impact factor: 2.740

5.  Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors.

Authors:  Marc J Nieuwenhuijse; Arian R Van Erkel; P D Sander Dijkstra
Journal:  Spine J       Date:  2011-09-01       Impact factor: 4.166

6.  Biomechanics of vertebral bone augmentation.

Authors:  Celene Hadley; Omer Abdulrehman Awan; Gregg H Zoarski
Journal:  Neuroimaging Clin N Am       Date:  2010-05       Impact factor: 2.264

7.  Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

Authors:  I H Lieberman; S Dudeney; M K Reinhardt; G Bell
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

8.  Revision surgery after vertebroplasty or kyphoplasty.

Authors:  Kee-Yong Ha; Ki-Won Kim; Young-Hoon Kim; In-Soo Oh; Sang-Won Park
Journal:  Clin Orthop Surg       Date:  2010-11-05

9.  Percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures: evaluation after 36 months.

Authors:  S P J Muijs; M J Nieuwenhuijse; A R Van Erkel; P D S Dijkstra
Journal:  J Bone Joint Surg Br       Date:  2009-03

10.  Complications of percutaneous vertebroplasty: An analysis of 1100 procedures performed in 616 patients.

Authors:  Agnieszka Saracen; Zbigniew Kotwica
Journal:  Medicine (Baltimore)       Date:  2016-06       Impact factor: 1.889

View more