Literature DB >> 32291536

A hydroxyl-functionalized homochiral porous organic cage for gas chromatographic separations.

Hong-Xing Li1, Tian-Peng Xie1, Ke-Qian Yan1, Sheng-Ming Xie1, Bang-Jin Wang1, Jun-Hui Zhang2, Li-Ming Yuan3.   

Abstract

A hydroxyl-functionalized homochiral porous organic cage (POC) was synthesized and characterized by FTIR, NMR, thermogravimetric analysis (TGA), MALDI-TOF-MS, and elemental analysis. The synthesized homochiral POC was used as stationary phase to prepare a capillary gas chromatography (GC) column by a static coating method. The fabricated column shows excellent selectivity not only for the separation of positional isomers but also for the resolution of various racemates. Thirty-nine racemates have been resolved on the column, including alcohols, diols, halohydrocarbons, epoxides, esters, lactones, ketones, ethers, and organic acids. Compared to the commercial β-DEX 120 column and previously reported chiral POCs (CC3-R, CC9, and CC10)-coated columns, there are 11, 10, 24, and 15 tested racemates that cannot be resolved on β-DEX 120 column, CC3-R column, CC9 column, and CC10 column, respectively. This reveals that the fabricated column has prominent complementarity or superior separation performance to these columns in enantioseparation. Besides, the fabricated column can achieve some enantioseparations which are not possible using all previously reported chiral POC-based columns. Some positional isomers (xylenes, dichlorobenzenes, dibromobenzenes, nitrochlorobenzenes, and nitrobromobenzenes) were also separated with high-resolution values. The column exhibits good repeatability, reproducibility, and stability. The relative standard deviation (RSD) values of retention times were 0.03-0.18%, 0.11-0.92%, and 2.1-6.6% for run-to-run (n = 5), day-to-day (n = 5), and column-to-column (n = 3), respectively. The experimental results demonstrate the great potential of POCs for practical application in GC. Graphical Abstract A hydroxyl-functionalized homochiral porous organic cage was used as stationary phase for gas chromatography separation of racemates and positional isomers. The resolution of racemates mainly depended on hydrogen bonding, π-interaction, host-guest inclusion, steric fit, etc., while separation of positional isomers by shape-selective guest binding.

Entities:  

Keywords:  Capillary column; Chiral separation; Chiral stationary phase; Gas chromatography; Porous organic cage; Positional isomers; Racemates

Year:  2020        PMID: 32291536     DOI: 10.1007/s00604-020-04252-4

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  26 in total

1.  A shape-persistent organic molecular cage with high selectivity for the adsorption of CO2 over N2.

Authors:  Yinghua Jin; Bret A Voss; Richard D Noble; Wei Zhang
Journal:  Angew Chem Int Ed Engl       Date:  2010-08-23       Impact factor: 15.336

2.  Porous organic cages.

Authors:  Tomokazu Tozawa; James T A Jones; Shashikala I Swamy; Shan Jiang; Dave J Adams; Stephen Shakespeare; Rob Clowes; Darren Bradshaw; Tom Hasell; Samantha Y Chong; Chiu Tang; Stephen Thompson; Julia Parker; Abbie Trewin; John Bacsa; Alexandra M Z Slawin; Alexander Steiner; Andrew I Cooper
Journal:  Nat Mater       Date:  2009-10-25       Impact factor: 43.841

3.  Chiral porous organic frameworks for asymmetric heterogeneous catalysis and gas chromatographic separation.

Authors:  Jinqiao Dong; Yan Liu; Yong Cui
Journal:  Chem Commun (Camb)       Date:  2014-12-11       Impact factor: 6.222

4.  Molecular shape sorting using molecular organic cages.

Authors:  Tamoghna Mitra; Kim E Jelfs; Marc Schmidtmann; Adham Ahmed; Samantha Y Chong; Dave J Adams; Andrew I Cooper
Journal:  Nat Chem       Date:  2013-01-20       Impact factor: 24.427

5.  Template synthesis of gold nanoparticles with an organic molecular cage.

Authors:  Ryan McCaffrey; Hai Long; Yinghua Jin; Aric Sanders; Wounjhang Park; Wei Zhang
Journal:  J Am Chem Soc       Date:  2014-01-24       Impact factor: 15.419

6.  A homochiral porous organic cage with large cavity and pore windows for the efficient gas chromatography separation of enantiomers and positional isomers.

Authors:  Jun-Hui Zhang; Sheng-Ming Xie; Bang-Jin Wang; Pin-Gang He; Li-Ming Yuan
Journal:  J Sep Sci       Date:  2018-01-25       Impact factor: 3.645

7.  Polydopamine-assisted immobilization of a zinc(II)-derived metal-organic cage as a stationary phase for open-tubular capillary electrochromatography.

Authors:  Zhentao Li; Zhenkun Mao; Zilin Chen
Journal:  Mikrochim Acta       Date:  2019-06-13       Impact factor: 5.833

8.  Novel inorganic mesoporous material with chiral nematic structure derived from nanocrystalline cellulose for high-resolution gas chromatographic separations.

Authors:  Jun-Hui Zhang; Sheng-Ming Xie; Mei Zhang; Min Zi; Pin-Gang He; Li-Ming Yuan
Journal:  Anal Chem       Date:  2014-09-17       Impact factor: 6.986

Review 9.  The significance of chirality in drug design and development.

Authors:  W H Brooks; W C Guida; K G Daniel
Journal:  Curr Top Med Chem       Date:  2011       Impact factor: 3.295

10.  Highly selective separation of enantiomers using a chiral porous organic cage.

Authors:  Jun-Hui Zhang; Sheng-Ming Xie; Bang-Jin Wang; Pin-Gang He; Li-Ming Yuan
Journal:  J Chromatogr A       Date:  2015-11-26       Impact factor: 4.759

View more
  1 in total

1.  Organic transformations in the confined space of porous organic cage CC2; catalysis or inhibition.

Authors:  Ayesha Mukhtar; Sehrish Sarfaraz; Khurshid Ayub
Journal:  RSC Adv       Date:  2022-08-26       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.