Fluorophotometric measurement of human tear turnover rate.

J R Occhipinti1, M A Mosier, J LaMotte, G T Monji.   

Abstract

Measurement of tear turnover rate using an automated scanning fluorophotometer (FluorotronR) was compared to Schirmer test results without anesthesia in young adults with no known ocular disorder. After the instillation of fluorescein, tear film fluorescence, expressed as fluorescein concentration equivalent, decreased exponentially in a linear fashion with time. The mean tear turnover rate was 30% per minute. Contact lens wearers had higher mean tear turnover rates when compared with non-contact lens wearers, but differences were not statistically significant. Half of tested eyes demonstrated total wetting of Schirmer Tear Test StripsR. Higher mean tear turnover rates were associated with complete wetting of the Schirmer test strips. There was no significant correlation between Schirmer paper wetting of less than 30 mm and fluorescein turnover rate.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3229126     DOI: 10.3109/02713688809015145

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  11 in total

Review 1.  Ocular drug delivery. Pharmacokinetic considerations.

Authors:  R D Schoenwald
Journal:  Clin Pharmacokinet       Date:  1990-04       Impact factor: 6.447

Review 2.  The international workshop on meibomian gland dysfunction: report of the diagnosis subcommittee.

Authors:  Alan Tomlinson; Anthony J Bron; Donald R Korb; Shiro Amano; Jerry R Paugh; E Ian Pearce; Richard Yee; Norihiko Yokoi; Reiko Arita; Murat Dogru
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-03-30       Impact factor: 4.799

3.  Fluorescence lifetime imaging microscopy reveals quenching of fluorescein within corneal epithelium.

Authors:  Ben J Glasgow
Journal:  Exp Eye Res       Date:  2016-04-20       Impact factor: 3.467

4.  Development of ciprofloxacin-loaded contact lenses using fluorous chemistry.

Authors:  Guoting Qin; Zhiling Zhu; Siheng Li; Alison M McDermott; Chengzhi Cai
Journal:  Biomaterials       Date:  2017-01-31       Impact factor: 12.479

5.  Correlation of tear clearance rate and fluorophotometric assessment of tear turnover.

Authors:  K P Xu; K Tsubota
Journal:  Br J Ophthalmol       Date:  1995-11       Impact factor: 4.638

6.  Simultaneous evaluation of tear turnover and corneal epithelial permeability by fluorophotometry in normal subjects and patients with keratoconjunctivitis sicca (KCS).

Authors:  J D Nelson
Journal:  Trans Am Ophthalmol Soc       Date:  1995

7.  Frequent association of delayed tear clearance in ocular irritation.

Authors:  P Prabhasawat; S C Tseng
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 4.638

8.  Effect of eledoisin on tear volume and tear flow in humans as assessed by fluorophotometry.

Authors:  M Göbbels; J Selbach; M Spitznas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

9.  Determination of basal tear turnover in insulin-dependent diabetes mellitus patients by fluorophotometry.

Authors:  T R Stolwijk; J A van Best; H H Lemkes; R J de Keizer; J A Oosterhuis
Journal:  Int Ophthalmol       Date:  1991-11       Impact factor: 2.031

10.  Measurement of basal tear turnover using a standardized protocol. European concerted action on ocular fluorometry.

Authors:  J A van Best; J M Benitez del Castillo; L M Coulangeon
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-01       Impact factor: 3.117

View more