Literature DB >> 32282357

Endothelial Cell Density Changes in the Corneal Center Versus Paracentral Areas After Descemet Membrane Endothelial Keratoplasty.

Aytan Musayeva1,2, Eitan Livny1,2, Diana C Dragnea1,2, Lisanne Ham1,2,3, Indrė Vasiliauskaitė1, Sorcha Ní Dhubhghaill1,2,3, Korine van Dijk1,2, Silke Oellerich1, Gerrit R J Melles1,2,4.   

Abstract

PURPOSE: To analyze whether endothelial cell density (ECD) differs between central and paracentral areas after Descemet membrane endothelial keratoplasty (DMEK) and to identify the locations of the highest and lowest ECD.
METHODS: In this retrospective cohort study, central and paracentral ECDs of 30 eyes of 30 patients who underwent DMEK for Fuchs endothelial corneal dystrophy were evaluated. Central, superonasal, superotemporal, and inferior specular microscopic images were analyzed at 1, 3, 6, 9, and 12 months after DMEK. Changes in ECD by location and over time and changes in location for the highest and lowest ECD were evaluated.
RESULTS: When compared with the preoperative donor ECD, the central ECD decreased by 32 (±11)% at 12 months postoperatively. ECD decline between 1 and 12 months postoperatively in the central, inferior, superonasal, and superotemporal location were 7%, 12%, 16%, and 13%, respectively (P < 0.0001 for all locations). Mean ECD was the highest in the center between the 3- to 12-month follow-up, whereas mean ECD was the lowest in the paracentral superonasal area at all time points (P < 0.001). Mean ECD of the highest and lowest density locations differed at all follow-up time points (P < 0.003).
CONCLUSIONS: Postoperative ECD was not found to be uniform across the graft. Contrary to the density distribution in the normal endothelium, paracentral area ECDs were found to be consistently lower than in the central area. These differences were most prominent in the superonasal area and persisted 12 months postoperatively. Central ECD after DMEK might, thus, not represent an accurate proxy for cell density of the entire graft.

Entities:  

Mesh:

Year:  2020        PMID: 32282357     DOI: 10.1097/ICO.0000000000002326

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  2 in total

1.  Identification of the preoperative and perioperative factors that predict postoperative endothelial cell density after Descemet membrane endothelial keratoplasty: A retrospective cohort study.

Authors:  Dimitri Chaussard; Florian Bloch; Arpiné Ardzivian Elnar; Yinka Zevering; Jean-Charles Vermion; Rémi Moskwa; Jean-Marc Perone
Journal:  PLoS One       Date:  2022-02-24       Impact factor: 3.240

2.  Effects of femtosecond laser-assisted trephination on donor tissue in liquid interface as compared to applanated interface.

Authors:  Ruth Donner; Gerald Schmidinger
Journal:  Acta Ophthalmol       Date:  2021-07-26       Impact factor: 3.988

  2 in total