Literature DB >> 32281041

Non-invasive electroanatomic mapping to reduce mapping time during catheter ablation of outflow tract ventricular premature depolarizations.

Stavros E Mountantonakis1, Kristie M Coleman2, Aditi S Vaishnav2, Jamie Shein2, Parth Makker2, Moussa Saleh2, Kabir Bhasin2, Neil E Bernstein2, Nicholas T Skipitaris2.   

Abstract

PURPOSE: Ventricular premature depolarizations (VPD) commonly arise from the septal anterior right ventricular outflow tract (sRVOT), the left coronary cusp (LCC), and the distal great cardiac vein (dGCV), and share common ECG characteristics. To assess the diagnostic accuracy of non-invasive electroanatomic mapping (NIEAM) in differentiating VPD origin between sRVOT, LCC and dGCV and quantify its clinical utility in eliminating unnecessary mapping and ablation.
METHODS: ECGs and NIEAMs (CardioInsight, Medtronic) from 32 patients (56.3 ± 15.2 years) undergoing ablation for VPDs originating from sRVOT, LCC, or dGCV were blindly reviewed for their diagnostic accuracy in predicting the SOO. A 2-step algorithm using NIEAM-based activation timing of the superior basal septum of < 22.5 ms and lateral mitral annulus of > 60.5 ms was compared with subjective ECG evaluation, the maximum deflection index (MDI), and the V2 transitional ratio in predicting SOO. We calculated the mapping and ablation time that could have been avoided had the operators relied on activation timing by NIEAM in designing their mapping and ablation strategy.
RESULTS: NIEAM was superior to subjective ECG evaluation, MDI, and V2 transition ratio in predicting the SOO yielding a sensitivity and specificity of 96.9% and 98.4% respectively. Using NIEAM in determining the SOO would have obviated 22 ± 4.5 min of mapping in the wrong chamber and prevented unnecessary ablation of 4.5 ± 1.8 min.
CONCLUSION: NIEAM has high diagnostic accuracy in differentiating between sRVOT, LCC, and dGCV VPDs, and can significantly reduce mapping time, obviating the need for unnecessary access and ablation.

Entities:  

Keywords:  Body surface mapping; Catheter ablation; Non-invasive electroanatomic mapping; Premature ventricular contraction; Ventricular arrhythmia

Year:  2020        PMID: 32281041     DOI: 10.1007/s10840-020-00731-z

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  2 in total

1.  QRS complex maximum deflection index in aortic cusp premature ventricular complexes.

Authors:  Konstantinos C Siontis; Malini Madhavan; Suraj Kapa; Samuel J Asirvatham; Peter A Noseworthy
Journal:  Int J Cardiol Heart Vasc       Date:  2015-02-07

2.  Noninvasive epicardial and endocardial mapping of premature ventricular contractions.

Authors:  Erik Wissner; Amiran Revishvili; Andreas Metzner; Alexey Tsyganov; Vitaly Kalinin; Christine Lemes; Ardan M Saguner; Tilman Maurer; Sebastian Deiss; Oleg Sopov; Eugene Labarkava; Mikhail Chmelevsky; Karl-Heinz Kuck
Journal:  Europace       Date:  2017-05-01       Impact factor: 5.214

  2 in total