Mechanical heart valves left in situ at the time of left ventricular assist device (LVAD) implantation are thought to potentially increase the risk of thromboembolism. Recommendations exist to replace dysfunctional mechanical mitral valves and any mechanical aortic valves at the time of LVAD implantation. Due to potential increases in cardiopulmonary bypass time and associated comorbidities with valve replacement, leaving a functional mechanical valve in place at LVAD implantation has been suggested to be a safe option. We retrospectively reviewed all patients with prior mechanical mitral or aortic valves undergoing LVAD implantation at our center between 2012 and 2017. Echocardiograms were read by a single cardiologist to assess for mechanical valve dysfunction. We identified 15 patients. Five patients had major bleeding requiring transfusion. On follow-up, 2 patients had hemorrhagic stroke and 2 had transient ischemic attach/ischemic stroke. In addition, 2 patients had LVAD thrombosis and 2 patients had LVAD driveline malfunction. Mild mechanical valve regurgitation was identified on follow-up echocardiograms of 2 patients. Rate of complications in patients with mechanical valves undergoing LVAD implantation was comparable to that reported for the general LVAD population. Leaving a functional mechanical valve in place at the time of LVAD implantation could be a reasonable alternative to valve replacement. More data are required to further guide patient care in these individuals.
© 2020 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  left ventricular assist devices; mechanical circulatory support; mechanical heart valves

Year:  2020        PMID: 32279355     DOI: 10.1111/aor.13702

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  1 in total

1.  Thrombosed stuck mitral valve during advanced mechanical circulatory support for post-cardiotomy shock.

Authors:  Yoshiyuki Takami; Naoki Hoshino; Hiroshi Ishikawa; Kiyotoshi Akita; Yusuke Sakurai; Kentaro Amano; Hideo Izawa; Yasushi Takagi