Literature DB >> 32277789

Polyoxomolybdate368 /polyaniline nanocomposite as a novel fiber for solid-phase microextraction of antidepressant drugs in biological samples.

Hossein Salar Amoli1, Yadollah Yamini2, Hossein Darmani1.   

Abstract

A novel solid-phase microextraction fiber was synthesized by coating a stainless steel wire with polyoxomolybdate368 /polyaniline as a sorbent aimed at extraction of amitriptyline, nortriptyline, and doxepin as antidepressant drugs from urine and blood samples. The polyoxomolybdate368 /polyaniline composite coating was applied using electropolymerization process under constant potential. This composition leads to enhanced extraction efficiency of the fiber. Scanning electron microscopy images show that huge three-dimensional structures of polyoxomolybdate368 in composite induced more non-smooth and porous fiber. In order to optimize of the extraction process, a series of variables including concentration of the composite materials, coating thickness, pH, extraction time, salt addition, and stirring rate was investigated and optimum conditions were determined. Analysis of surface morphology and chemical composition was performed. High-performance liquid chromatography was used for separation and evaluation of mentioned antidepressant drugs from the matrixes. The experiments indicated a detection limits of <0.2 ng/L and a linear dynamic range of 0.3-100 ng/L (R2  > 0.994). The relative recovery values were found to be in the range of 92-98%. It was concluded that the purposed fiber is highly efficient in analyzing traces of antidepressant drugs in urine and blood.
© 2020 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  antidepressant drugs; nanocomposite; polyaniline; polyoxomolybdate; solid-phase microextraction

Mesh:

Substances:

Year:  2020        PMID: 32277789     DOI: 10.1002/jssc.201901152

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  2 in total

1.  Stir bar sorptive-dispersive microextraction by a poly(methacrylic acid-co-ethylene glycol dimethacrylate)-based magnetic sorbent for the determination of tricyclic antidepressants and their main active metabolites in human urine.

Authors:  Víctor Vállez-Gomis; Sara Exojo-Trujillo; Juan L Benedé; Alberto Chisvert; Amparo Salvador
Journal:  Mikrochim Acta       Date:  2022-01-08       Impact factor: 5.833

2.  New Method for the Monitoring of Antidepressants in Oral Fluid Using Dried Spot Sampling.

Authors:  Sofia Soares; Tiago Rosado; Mário Barroso; Eugenia Gallardo
Journal:  Pharmaceuticals (Basel)       Date:  2021-12-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.