Electrochemical attack and corrosion of platinum electrodes in dielectrophoretic diagnostic devices.

Daniel P Heineck1, Benjamin Sarno2, Sejung Kim2, Michael Heller3,4.   

Abstract

Though the advances in microelectronic device fabrication have realized new capabilities in integrated analytical and diagnostic platforms, there are still notable limitations in point-of-care sample preparation. AC electrokinetic devices, especially those leveraging dielectrophoresis (DEP), have shown potential to solve these limitations and allow for sample-to-answer in a single point-of-care device. However, when working directly with whole blood or other high conductance (~ 1 S/m) biological fluids, the aggressive electrochemical conditions created by the electrode can fundamentally limit the device operation. In this study, platinum wire-based electrode devices spanning circular polytetrafluorethylene (PTFE) wells and a planar microarray device with sputtered platinum electrodes were tested in plasma and PBS buffers of differing concentration across a wide range of frequencies and electric field intensities (AC voltages) to determine their respective safe regions of operation and to gain an understanding about the failure mechanisms of this class of device. At frequencies of 10 kHz and below, the upper bound of operation is the degradation of electrodes due to electrochemical attack by chlorine overcoming the native platinum oxide passivation. At higher frequencies, 100 kHz and above, the dielectric loss and subsequent heating of the buffer will boil before the electrodes suffer observable damage, due to the slow irreversible reaction kinetics. Effective dielectrophoretic capture of small biological particles at these frequencies is limited, and heat/oxidative denaturation of target material are a major concern. A new class of smaller devices, ones capable of high throughput at voltages low enough to maintain the integrity of the platinum passivation layer, is needed to mitigate these fundamental limitations.

Entities:  

Keywords:  Corrosion; Dielectrophoresis; Electrochemistry; Electrokinetics; Liquid biopsy; Point-of-care

Mesh:

Substances:

Year:  2020        PMID: 32277243     DOI: 10.1007/s00216-020-02607-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  1 in total

1.  Theoretical and experimental analysis of negative dielectrophoresis-induced particle trajectories.

Authors:  Ramona Luna; Daniel P Heineck; Elmar Bucher; Laura Heiser; Stuart D Ibsen
Journal:  Electrophoresis       Date:  2022-05-15       Impact factor: 3.595

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.