Literature DB >> 32275206

On-the-fly rapid immunoassay for neonatal sepsis diagnosis: C-reactive protein accurate determination using magnetic graphene-based micromotors.

Águeda Molinero-Fernández1, Luis Arruza2, Miguel Ángel López3, Alberto Escarpa4.   

Abstract

Based on the exceptional and new opened biosensing possibilities of self-propelled micromotors, a micromotor-based immunoassay (MIm) has smartly been designed for C-reactive protein (CRP) determination in plasma of preterm infants with sepsis suspicion. The design of the micromotors involved the electrosynthesis of a carbon-based outer layer (for antibody functionalization), an intermediate Ni layer (for magnetic guidance and stopped flow operations) and PtNPs inner catalytic layer (for catalytic bubble propulsion). Micromotors biofunctionalization on the outer layer (using carbon black (CB), reduced graphene oxide (rGO) and multi-walled carbon nanotubes (MWCNTs), and biocompatible propulsion capabilities, were carefully studied. Magnetic rGO/Ni/PtNPs micromotors exhibited the most efficient and reproducible (CV = 9%) anti-CRP functionalization, controlled stopped-flow operations as well as efficient bubble propulsion (1% H2O2, 1,5% NaCh, speed 140 μm s-1). Analytical performance of MIm was excellent, allowing the direct (without dilution), sensitive (LOD = 0.80 μg/mL), and accurate CRP determination (Er = 1%) in hardly available preterm babies' plasma samples with suspected sepsis using very low volumes (<10 μL) and in just 5 min of on-the-fly bioassay. Overall, the results obtained allowed the fast and reliable sepsis diagnostics in preterm babies' individuals with suspected sepsis, not only proving the usefulness of the approach as its potential utilization as point-of-care device for clinical analysis but drawing new horizons in extremely low sample volumes-based diagnostics.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  C-reactive protein; Carbon nanomaterials; Electrochemical detection; Micromotors; On-the-fly immunoassay; Sepsis

Mesh:

Substances:

Year:  2020        PMID: 32275206     DOI: 10.1016/j.bios.2020.112156

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  10 in total

1.  Bio-compatible miniature viscosity sensor based on optical tweezers.

Authors:  Shun Yuan; Qing Zheng; Benjun Yao; Mingcong Wen; Weina Zhang; Jie Yuan; Hongxiang Lei
Journal:  Biomed Opt Express       Date:  2022-02-01       Impact factor: 3.732

2.  Electrochemical aptasensor based on anisotropically modified (Janus-type) gold nanoparticles for determination of C-reactive protein.

Authors:  Anabel Villalonga; Alfredo Sánchez; Diana Vilela; Beatriz Mayol; Paloma Martínez-Ruíz; Reynaldo Villalonga
Journal:  Mikrochim Acta       Date:  2022-08-02       Impact factor: 6.408

3.  Functionalized ultra-fine bimetallic PtRu alloy nanoparticle with high peroxidase-mimicking activity for rapid and sensitive colorimetric quantification of C-reactive protein.

Authors:  Pramod K Gupta; Seong Eun Son; Gi Hun Seong
Journal:  Mikrochim Acta       Date:  2021-03-09       Impact factor: 5.833

Review 4.  Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine - a review.

Authors:  Robert D Crapnell; Nina C Dempsey; Evelyn Sigley; Ascanio Tridente; Craig E Banks
Journal:  Mikrochim Acta       Date:  2022-03-12       Impact factor: 6.408

Review 5.  Advances in sepsis diagnosis and management: a paradigm shift towards nanotechnology.

Authors:  Amit Pant; Irene Mackraj; Thirumala Govender
Journal:  J Biomed Sci       Date:  2021-01-08       Impact factor: 8.410

6.  Wave-shaped microfluidic chip assisted point-of-care testing for accurate and rapid diagnosis of infections.

Authors:  Bin-Feng Yin; Xin-Hua Wan; Ming-Zhu Yang; Chang-Cheng Qian; A S M Muhtasim Fuad Sohan
Journal:  Mil Med Res       Date:  2022-02-11

7.  A bioinspired bubble removal method in microchannels based on angiosperm xylem embolism repair.

Authors:  Lihua Guo; Yuanchang Liu; Penghui Ran; Gang Wang; Jie Shan; Xudong Li; Chong Liu; Jingmin Li
Journal:  Microsyst Nanoeng       Date:  2022-03-22       Impact factor: 7.127

8.  Self-Propelled Multifunctional Microrobots Harboring Chiral Supramolecular Selectors for "Enantiorecognition-on-the-Fly".

Authors:  Jose Muñoz; Mario Urso; Martin Pumera
Journal:  Angew Chem Int Ed Engl       Date:  2022-02-09       Impact factor: 16.823

Review 9.  Biocompatible micromotors for biosensing.

Authors:  Roberto Maria-Hormigos; Beatriz Jurado-Sánchez; Alberto Escarpa
Journal:  Anal Bioanal Chem       Date:  2022-08-31       Impact factor: 4.478

10.  Mechanically Optimize T Cells Activation by Spiky Nanomotors.

Authors:  Dongmei Fu; Dazhi Xie; Fei Wang; Bin Chen; Zhen Wang; Fei Peng
Journal:  Front Bioeng Biotechnol       Date:  2022-02-22
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.