Hiroaki Hiraiwa1, Takahiro Okumura1, Shinya Shimizu1,2, Yoshihito Arao1, Hideo Oishi1, Hiroo Kato1, Tasuku Kuwayama1, Shogo Yamaguchi1, Tomoaki Haga1, Tsuyoshi Yokoi1, Toru Kondo1, Yuki Sugiura1, Naoaki Kano1, Naoki Watanabe1, Kenji Fukaya1, Kenji Furusawa1, Akinori Sawamura1, Ryota Morimoto1, Kazuro Fujimoto3, Masato Mutsuga3, Akihiko Usui3, Toyoaki Murohara1.
Abstract
We herein report the long-term changes in cardiac function and pathological findings after successful explantation of a left ventricular assist device in a 42-year-old patient with anthracycline-induced cardiomyopathy with reworsening heart failure. Endomyocardial biopsy samples revealed that the cardiomyocyte diameter decreased and collagen volume fraction increased just after left ventricular assist device explantation. The collagen volume fraction decreased after 6 months, despite preserved systolic function. At 5 years after left ventricular assist device explantation, the systolic function markedly decreased and cardiomyocyte diameter increased. Pathological changes of the myocardium may enable the identification of cardiac dysfunction prior to echocardiographic changes in patients with reworsening heart failure after left ventricular assist device explantation.Entities:
Keywords: anthracycline-induced cardiomyopathy; cardiac pathology; left ventricular assist device; reworsening heart failure
Mesh:
Substances:
Year: 2020 PMID: 32273641 PMCID: PMC7103868 DOI: 10.18999/nagjms.82.1.129
Source DB: PubMed Journal: Nagoya J Med Sci ISSN: 0027-7622 Impact factor: 1.131
Fig. 1Echocardiographic data, plasma BNP level, and myocardial pathology images.
LVEF: left ventricular ejection fraction, LVDD: left ventricular end-diastolic diameter, BNP: brain natriuretic peptide, LVAD: left ventricular assist device, LVAD-implant: just before LVAD implantation, LVAD-explant: just after LVAD explantation, 6 months: 6 months after LVAD explantation, 5 years: 5 years after LVAD explantation.
Fig. 2Endomyocardial biopsy samples revealed changes in cardiomyocyte diameter (A) and collagen volume fraction (B).
Data are expressed in box plots; box, interquartile range; horizontal line, median; whiskers, range.