Literature DB >> 32272229

High-power, short-duration atrial fibrillation ablations using contact force sensing catheters: Outcomes and predictors of success including posterior wall isolation.

Roger A Winkle1, R Hardwin Mead2, Gregory Engel2, Melissa H Kong2, Jonathan Salcedo2, Chad R Brodt3, Rob A Patrawala2.   

Abstract

BACKGROUND: Little is known about the long-term outcomes and predictors of success of high-power, short-duration (HPSD) contact force (CF) atrial fibrillation (AF) ablations.
OBJECTIVE: The purpose of this study was to determine long-term freedom from AF and predictors of freedom from AF for 50-W, 5- to 15-second CF ablation.
METHODS: We examined 4-year outcomes and predictors of freedom from AF after AF ablation for 1250 consecutive patients undergoing HPSD CF ablations.
RESULTS: Patient demographics were age 66.6 ± 10.5 years, female 30.9%, left atrial (LA) size 4.26 ± 0.66 cm, paroxysmal AF 35.7%, persistent AF 56.6%, and longstanding AF 7.7%. Initial ablation times were procedure 114.2 ± 45.9 minutes, fluoroscopy 15.5 ± 11.5 minutes, and total radiofrequency 20.6 ± 7.7 minutes. TactiCath was used in 47.7%, SmartTouch in 52.3%, and posterior wall isolation (PWI) was performed in 34%. Four-year freedom from AF after multiple ablations were paroxysmal AF 87.0%, persistent AF 71.9%, and longstanding AF 64.9%. Single procedure success was 74.9% for TactiCath, 64.7% for SmartTouch (P <.001), and 73.0% for no PWI vs 58.9% for PWI (P <.0001). PWI did not change outcomes for paroxysmal AF but had worse outcomes for nonparoxysmal AF. Multivariate analysis showed 6 independent predictors of worse outcome after initial ablation: older age (P = .014), female gender (P <.0001), persistent AF (P = .0001), larger LA size (P <.001), PWI (P = .049), and use of SmartTouch vs TactiCath catheter (P = .007). Redo ablations were performed in 13.8%, and the outcome was better when more veins had reconnected after the initial ablation and when AF was paroxysmal.
CONCLUSION: Analysis revealed 6 independent predictors of outcome for HPSD CF. At redo ablations, the outcome was better if more veins had reconnected and could be re-isolated.
Copyright © 2020 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Ablation; Ablation outcomes; Atrial fibrillation; Contact force; High-power short-duration

Year:  2020        PMID: 32272229     DOI: 10.1016/j.hrthm.2020.03.022

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  8 in total

1.  Meta-analysis comparing outcomes of high-power short-duration and low-power long-duration radiofrequency ablation for atrial fibrillation.

Authors:  Dibbendhu Khanra; Abdul Hamid; Saurabh Deshpande; Anindya Mukherjee; Sanjiv Petkar; Mohammad Saeed; Indranill Basu-Ray
Journal:  Anatol J Cardiol       Date:  2022-01       Impact factor: 1.596

2.  Ablation index-guided 50W radiofrequency ablation for left atrial posterior wall isolation in atrial fibrillation.

Authors:  Wern Yew Ding; Lilith Tovmassian; Cedric Bierme; Nikola Kozhuharov; Richard L Snowdon; Dhiraj Gupta
Journal:  Indian Pacing Electrophysiol J       Date:  2022-05-26

Review 3.  Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation.

Authors:  Xuerong Sun; Jiang Lu; Jinxuan Lin; Tianjie Feng; Ni Suo; Lihui Zheng; Zhimin Liu; Gang Chen; Xiaohan Fan; Shu Zhang; Guodong Niu
Journal:  Cardiol Res Pract       Date:  2021-02-15       Impact factor: 1.866

4.  The efficacy of high-power short-duration radiofrequency for atrial fibrillation ablation: A protocol for systematic review and meta-analysis.

Authors:  Peng Zhang; Ling Ma; Fei Wang; Liang Shi
Journal:  Medicine (Baltimore)       Date:  2021-04-23       Impact factor: 1.817

Review 5.  Comparison of Effectiveness and Safety between High-Power Short-Duration Ablation and Conventional Ablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.

Authors:  Shuyu Jin; Lu Fu; Junrong Jiang; Xingdong Ye; Huiyi Liu; Yanlin Chen; Sijia Pu; Shulin Wu; Yumei Xue
Journal:  J Interv Cardiol       Date:  2022-08-16       Impact factor: 1.776

6.  Long-Term Results of Pulmonary Vein Isolation Plus Modified Posterior Wall Debulking Utilizing High-Power Short-Duration Strategy: An All-Comers Study in Real World.

Authors:  Başar Candemir; Emir Baskovski; Osman Beton; Volkan Kozluca; Türkan Seda Tan; Timuçin Altın; Eralp Tutar
Journal:  Anatol J Cardiol       Date:  2022-06       Impact factor: 1.475

7.  First clinical experience of high-power ablation of atrial fibrillation with a novel contact force-sensing gold-tip catheter.

Authors:  Abdul Shokor Parwani; Adrian Jayanata; Robin Kraft; Philipp Lacour; Florian Blaschke; Burkert Pieske; Leift-Hendrik Boldt
Journal:  Cardiol J       Date:  2022-06-28       Impact factor: 3.487

Review 8.  Update on management of atrial fibrillation in heart failure: a focus on ablation.

Authors:  Bart A Mulder; Michiel Rienstra; Isabelle C Van Gelder; Yuri Blaauw
Journal:  Heart       Date:  2021-06-04       Impact factor: 5.994

  8 in total