Literature DB >> 32271525

Refractive outcomes of 8 biometric formulas in combined phacovitrectomy with internal limiting membrane peeling for epiretinal membrane.

Efstathios Vounotrypidis1, Mehdi Shajari, Daniel R Muth, Nino Hirnschall, Oliver Findl, Siegfried Priglinger, Wolfgang J Mayer.   

Abstract

PURPOSE: To investigate the accuracy of 8 different biometric formulas in combined phacovitrectomy and the effect of constant optimization on refractive outcome.
SETTING: Ludwig-Maximilians-University, Munich, Germany.
DESIGN: Retrospective observational case series.
METHODS: In this single-center study, patients with cataract and epiretinal membrane who underwent combined phacovitrectomy with internal limiting membrane peeling (Group B) and axial length-matched patients who underwent phacoemulsification (Group A) were included. In Group C, optimized constants from Group A were applied in patients of Group B. One eye of each patient was included. Main outcome measures after constant optimization for each biometric formula were refractive prediction error (PE), mean absolute error (MAE), and percentages of eyes with a PE within ±0.25 diopters (D), ±0.5 D, and ±1.0 D.
RESULTS: The study comprised 128 patients. For all formulas in Group A and Group B, refractive PE was 0.000 (P = .964 and P = .967, respectively). For formulas Barrett, Haigis, Hill, Hoffer Q, Holladay 1, Holladay 2, Kane, and SRK-T, refractive PE was -0.147, -0.204, -0.180, -0.212, -0.180, -0.178, -0.153, and -0.159, respectively, in Group C (P = .569); MAE was 0.346, 0.375, 0.382, 0.379, 0.355, 0.377, 0.318, and 0.364, respectively, in Group A (P = .286); 0.402, 0.422, 0.417, 0.427, 0.417, 0.402, 0.370, and 0.401, respectively, in Group B (P = .364); and 0.401, 0.424, 0.419, 0.444, 0.424, 0.404, 0.391, and 0.422, respectively, in Group C (P = .767). Effect of constant optimization in phacovitrectomy was statistically significant for all formulas (P < .001 for each formula).
CONCLUSIONS: No statistically significant difference was observed between the biometric formulas with regard to PE and MAE. However, in terms of phacovitrectomy, constant optimization should be considered for individual intraocular lens power calculations attributable to myopic shift.

Entities:  

Mesh:

Year:  2020        PMID: 32271525     DOI: 10.1097/j.jcrs.0000000000000087

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  1 in total

1.  Prospective comparison of accuracy of intraocular lens calculation formulas in phacovitrectomy: a pilot study in a real-world clinical practice.

Authors:  Tatsuhiko Sato; Emiko Iimori; Ken Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-25       Impact factor: 3.535

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.