Literature DB >> 32271486

Static and Fatigue Loading of Veneered Implant-Supported Fixed Dental Prostheses.

Mohammad M Rayyan1, Jihad Abdallah2, Lucette G Segaan1, Estevam A Bonfante3, Essam Osman1.   

Abstract

PURPOSE: This study aimed to compare the load to failure and the probability of survival of porcelain fused to zirconia (PFZ) three-unit, implant-supported, fixed dental prostheses (FDPs) to those of indirect composites veneered to either zirconia (CVZ) or milled fiber-reinforced composite (FRC) frameworks under static and fatigue loading.
MATERIALS AND METHODS: One-hundred and twenty posterior three-unit FDP (second premolar pontic) frameworks were fabricated via milling from a single Standard Tessellation Language (STL) file. The FDPs were divided into three groups. Each group (n = 40) was subjected to static (n = 20) and fatigue (n = 20) loading tests, as follows: 1) PFZ: zirconia framework layered with porcelain veneer; 2) CVZ: zirconia framework veneered with indirect composite resin; and 3) FRC: FRC framework veneered with indirect composite resin. After porcelain veneering onto sintered zirconia frameworks, or resin composite veneering onto zirconia or FRC frameworks, FDPs were cemented on their abutments using self-adhesive resin cement. After thermal cycling, half of the FDPs were subjected to an accelerated fatigue test. The other half of the FDPs were subjected to single load-to-failure (SLF) testing at a crosshead speed (1 mm/min). Lifetime analysis was conducted to determine the probability of survival, and fractographic analysis was performed.
RESULTS: Significant differences were observed among the studied groups for SLF with the highest characteristic strength values observed for PFZ (2,154 N), followed by 1,905.47 N for CVZ and 1679.56 N for FRC. The probability of survival for 100,000 cycles at 500 N was the highest for FRC (98%) and CVZ (100%) and was significantly lower for PFZ (88%). Different fracture patterns were observed in the fractography.
CONCLUSIONS: In fatigue testing, which simulates masticatory function better than static tests, a higher probability of survival was observed for FRC and CVZ than for PFZ. Framework fractures were not observed only for the FRC group, indicating that chairside repair with the addition of indirect composite could be performed for continued function. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

Entities:  

Keywords:  Zirconia; fiber-reinforced composites; fracture; implants; lifetime

Year:  2020        PMID: 32271486     DOI: 10.1111/jopr.13173

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  2 in total

Review 1.  New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Authors:  Pinar Cevik; Martin Schimmel; Burak Yilmaz
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

2.  Thermal Load and Heat Transfer in Dental Titanium Implants: An Ex Vivo-Based Exact Analytical/Numerical Solution to the 'Heat Equation'.

Authors:  Grigorios P Panotopoulos; Ziyad S Haidar
Journal:  Dent J (Basel)       Date:  2022-03-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.