Literature DB >> 32270566

Comparison of touch-up ablation rate and pulmonary vein isolation durability between hot balloon and cryoballoon.

Rintaro Hojo1, Seiji Fukamizu1, Sayuri Tokioka1, Dai Inagaki1, Satoshi Miyazawa1, Iwanari Kawamura1, Takeshi Kitamura1, Harumizu Sakurada2, Masayasu Hiraoka3.   

Abstract

INTRODUCTION: This study aimed to compare touch-up ablation (TUA) rates and pulmonary vein isolation (PVI) durability of hot balloon ablation (HBA) and cryoballoon ablation (CBA) in paroxysmal atrial fibrillation (PAF) patients.
METHODS: In total, 137 PAF patients were enrolled in the study. Among them, 59 underwent two HBA procedures at 6-month intervals and 78 patients underwent two CBA sessions, both regardless of atrial fibrillation recurrence. Propensity score matching was performed to estimate similar patient characteristics between the HBA and CBA groups.
RESULTS: Each group comprised of 46 matched patients for comparison. The TUA rate at the first session was higher for HBA (49 of 184 PVs) than for CBA (20 PVs) (P = .01), with the highest incidence at the left superior pulmonary vein (LSPV). The rates of PVI durability at the second session performed 7 months later were similar between HBA (168 of 184 PVs) and CBA (162 PVs) groups. The PVI durability rate at the TUA sites of the first session was higher for HBA than for CBA (41 of 49 PVs vs 10 PVs, respectively; P = .01). Fifty percent of the patients underwent HBA at 73°C for the LSPV. HBA performed at 73°C yielded a lower TUA rate than that at 70°C (16 of 23 PVs vs 7 of 23 PVs; P = .008).
CONCLUSIONS: While PVI durability was similar between HBA and CBA, the TUA rate was higher for HBA than for CBA, especially on the LSPV. For LSPV, HBA at a balloon temperature of 73°C may reduce the TUA rate.
© 2020 Wiley Periodicals, Inc.

Entities:  

Keywords:  cryoballoon ablation; hot balloon ablation; paroxysmal atrial fibrillation; pulmonary vein isolation; touch-up ablation

Mesh:

Year:  2020        PMID: 32270566     DOI: 10.1111/jce.14485

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  3 in total

1.  Effects of Hot Balloon vs. Cryoballoon Ablation for Atrial Fibrillation: A Systematic Review, Meta-Analysis, and Meta-Regression.

Authors:  Xinyi Peng; Xiao Liu; Hongbo Tian; Yu Chen; Xuexun Li
Journal:  Front Cardiovasc Med       Date:  2021-12-15

2.  Impact of monitoring surface temperature during pulmonary vein isolation in a second-generation hot balloon system.

Authors:  Hiroshi Fukunaga; Yukio Sekiguchi; Sou Asano; Takahiko Nagase; Kohei Tanizaki; Jun Umemura; Junichi Nitta; Mitsuaki Isobe
Journal:  Int J Cardiol Heart Vasc       Date:  2022-02-03

3.  Early experiences with three types of balloon-based ablation catheters in patients with paroxysmal atrial fibrillation.

Authors:  Atsushi Kobori; Yasuhiro Sasaki; Misun Pak; Taiji Okada; Toshiaki Toyota; Kitae Kim; Takeshi Kitai; Natsuhiko Ehara; Makoto Kinoshita; Shuichiro Kaji; Yasuki Kihara; Yutaka Furukawa
Journal:  Heart Rhythm O2       Date:  2021-03-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.