| Literature DB >> 3225599 |
C J Fowler1, K Sitzoglou, Z Ali, P Halonen.
Abstract
With the current practice of measuring thresholds for warming and cooling separately, the question of the exact nature of afferents subserving these sensations assumes new importance. Experiments to measure reaction times to warming and cooling stimuli at two sites on the lower limb are described. The conduction velocity for each sensation was estimated from the conduction distance and conduction time in the limb. The estimated mean conduction velocity for warming was 0.5, SD 0.2 m/s and cooling 2.1, SD 0.8 m/s. These figures confirm that the sensation of warming is conveyed in unmyelinated and cooling in small myelinated peripheral nerve fibres.Entities:
Mesh:
Year: 1988 PMID: 3225599 PMCID: PMC1033021 DOI: 10.1136/jnnp.51.9.1164
Source DB: PubMed Journal: J Neurol Neurosurg Psychiatry ISSN: 0022-3050 Impact factor: 10.154