Literature DB >> 32255920

Hydrogen peroxide penetration into the pulp chamber during conventional in-office bleaching and diode laser-assisted bleaching with three different wavelengths.

Mahdi Abbasi1, Edris Pordel2, Nasim Chiniforush3, Sattar Gorgani Firuzjaee4, Ladan Ranjbar Omrani5.   

Abstract

BACKGROUND AND AIMS: Penetration of hydrogen peroxide into the pulp chamber and subsequent tooth hypersensitivity is a common concern in dental bleaching. The aim of this study was to assess the penetration of hydrogen peroxide (H2O2) into the pulp chamber in diode-laser activated bleaching with different laser wavelengths.
MATERIALS AND METHODS: Fifty extracted human maxillary anterior teeth were collected and divided into five groups(n = 10). Group 1: conventional in-office bleaching using Opalescence Boost gel. Group 2: Bleaching with Biolase Laser White 20 gel activated by 980 nm diode laser. Group 3: Bleaching with Biolase Laser White 20 gel activated by 810 nm diode laser. Group 4: Bleaching with Biolase Laser White 20 gel activated by 940 nm diode laser. Group 5: No bleaching control group.After bleaching, the solution into the pulp chamber was collected and analyzed using a spectrophotometer. The recorded data were compared with a standard sample and the results were analyzed and compared using one-way ANOVA and Tukey's HSD tests.
RESULTS: In all bleached groups, H2O2 had infiltrated into the pulp chamber. The highest level of penetration was noted in group 2 (2.32 ± 0.25 µg), while the lowest level was noted in group 3 (1.85 ± 0.33 µg). The difference in this regard was significant between groups 2 and 3 (P = 0.024), but the differences between other groups were not statistically significant (P ≥ 0.42).
CONCLUSION: Considering the results of this study, it can be stated that hydroge peroxide penetration in to pulp chamber in diode laser activation of bleaching agent according to manufactures instruction is not higher than in-office bleaching. The wavelength of diode laser had significant effect on penetration of hydrogen peroxide into pulp chamber. 2019, Japan Medical Laser Laboratory.

Entities:  

Keywords:  Bleaching, Laser; Diode; Hydrogen peroxide

Year:  2019        PMID: 32255920      PMCID: PMC7087340          DOI: 10.5978/islsm.19-OR-20

Source DB:  PubMed          Journal:  Laser Ther        ISSN: 0898-5901


  25 in total

1.  A Comparative Study of Enamel Surface Roughness After Bleaching With Diode Laser and Nd: YAG Laser.

Authors:  Mansoreh Mirzaie; Esmaiel Yassini; Saber Ganji; Zohreh Moradi; Nasim Chiniforush
Journal:  J Lasers Med Sci       Date:  2016-07-18

2.  Penetration of 38% hydrogen peroxide into the pulp chamber in bovine and human teeth submitted to office bleach technique.

Authors:  Samira Esteves Afonso Camargo; Marcia Carneiro Valera; Carlos Henrique Ribeiro Camargo; Maria Nadir Gasparoto Mancini; Marcia Maciel Menezes
Journal:  J Endod       Date:  2007-05-23       Impact factor: 4.171

3.  Hydrogen peroxide induces cell proliferation and apoptosis in pulp of rats after dental bleaching in vivo: Effects of the dental bleaching in pulp.

Authors:  Francine Benetti; João Eduardo Gomes-Filho; Luciana Louzada Ferreira; Edilson Ervolino; André Luiz Fraga Briso; Gustavo Sivieri-Araújo; Eloi Dezan-Júnior; Luciano Tavares Angelo Cintra
Journal:  Arch Oral Biol       Date:  2017-04-22       Impact factor: 2.633

4.  Effect of Adhesive Restoration and Bleaching Technique on the Concentration of Hydrogen Peroxide In the Pulp Chamber.

Authors:  V Cavalli; B G Silva; S B Berger; G Abuna; F C Marson; Cpm Tabchoury; M Giannini
Journal:  Oper Dent       Date:  2016-11-28       Impact factor: 2.440

5.  Effect of laser activated bleaching on the chemical stability and morphology of intracoronal dentin.

Authors:  Fabiane Carneiro Lopes; Renato Roperto; Anna Akkus; Ozan Akkus; Regina Guenka Palma-Dibb; Manoel Damião de Sousa-Neto
Journal:  Arch Oral Biol       Date:  2017-11-13       Impact factor: 2.633

6.  Penetration of the pulp chamber by bleaching agents in teeth restored with various restorative materials.

Authors:  O Gökay; F Yilmaz; S Akin; M Tunçbìlek; R Ertan
Journal:  J Endod       Date:  2000-02       Impact factor: 4.171

7.  Peroxide penetration into the pulp from whitening strips.

Authors:  Osman Gökay; Arzu Müjdeci; Evren Algn
Journal:  J Endod       Date:  2004-12       Impact factor: 4.171

8.  Color alteration, hydrogen peroxide diffusion, and cytotoxicity caused by in-office bleaching protocols.

Authors:  Letícia Cunha Amaral Gonzaga de Almeida; Diana Gabriela Soares; Marjorie Oliveira Gallinari; Carlos Alberto de Souza Costa; Paulo Henrique Dos Santos; André Luiz Fraga Briso
Journal:  Clin Oral Investig       Date:  2014-07-19       Impact factor: 3.573

9.  Bleaching effectiveness, hydrogen peroxide diffusion, and cytotoxicity of a chemically activated bleaching gel.

Authors:  Carla Caroline de Oliveira Duque; Diana Gabriela Soares; Fernanda Gonçalves Basso; Josimeri Hebling; Carlos Alberto de Souza Costa
Journal:  Clin Oral Investig       Date:  2013-11-22       Impact factor: 3.573

10.  The Effect of Delivery System and Light Activation on Tooth Whitening Efficacy and Hydrogen Peroxide Penetration.

Authors:  Soyoung Park; So Ran Kwon; Fang Qian; Philip W Wertz
Journal:  J Esthet Restor Dent       Date:  2016-08-11       Impact factor: 2.843

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.