Literature DB >> 32253379

Author Correction: Reconstruction of residents' thyroid equivalent doses from internal radionuclides after the Fukushima Daiichi nuclear power station accident.

Takashi Ohba1, Tetsuo Ishikawa2,3, Haruyasu Nagai4, Shinji Tokonami5, Arifumi Hasegawa6, Gen Suzuki7.   

Abstract

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

Entities:  

Year:  2020        PMID: 32253379      PMCID: PMC7136231          DOI: 10.1038/s41598-020-62931-x

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.996


Correction to: Scientific Reports 10.1038/s41598-020-60453-0, published online 27 February 2020 This Article contains errors in the Methods section under subheading ‘Estimation of TED via inhalation’ where, “FC is a correction factor for the dose coefficient because iodine uptake rate is 18.5% (SD 6.0%), lower than the 30% in the ICRP thyroid model, while thyroid volume in Japanese does not differ from that of ICRP reference man18. DF is a decontamination factor to reflect sheltering. In the present study we set FC to 0.62 (=18.5/30) and DF to 0.5, and the combined uncertainty interval of these two factors is simulated as described below.” should read: “FC is a correction factor for the dose coefficient because iodine uptake rate is 18.6% (SD 6.0%), lower than the 30% in the ICRP thyroid model, while thyroid volume in Japanese does not differ from that of ICRP reference man18. DF is a decontamination factor to reflect sheltering. In the present study we set FC to 0.62 (=18.6/30) and DF to 0.5, and the combined uncertainty interval of these two factors is simulated as described below.” The Article also contains an error in equation (3) in the Methods section under the subheading ‘Estimation of TED via ingestion in Iitate village’ where, should read: In addition, there is a typographical error in the Methods section under subheading ‘Uncertainty of correction factors’ where, “Likewise, the combined uncertainty of FC and Sf in formula (2) was simulated by setting FC as having a normal distribution with (18.6 +/−6.0)/30% and Sf as having a binomial distribution with denominator 100 and expected proportion 0.3.” should read: “Likewise, the combined uncertainty of FC and Sf in formula (3) was simulated by setting FC as having a normal distribution with (18.6 +/−6.0)/30% and Sf as having a binomial distribution with denominator 100 and expected proportion 0.3.” Finally, this Article contains errors in References 18 and 28 which are incorrectly given as: 18. Kudo, T. et al. Determination of the kinetic parameters for 123I uptake by thyroid, and thyroid weights and volumes, In present-day healthy Japanese volunteers. Health phys. In press (2019). 28. Fukushima Revitalization Station (Fukushima Prefecture Government). Relationship between estimated thyroid absorbed doses based on UNSCEAR 2013 report and the rate of detection of malignant or suspected malignancy by each municipality (No. 1-2), on 3 June 2019, http://www.pref.fukushima.lg.jp/site/portal/kenkocyosa-kentoiinkai-b13.html (2019). The correct references are listed below as References 1 and 2:
  2 in total

1.  Determination of the Kinetic Parameters for 123I Uptake by the Thyroid, Thyroid Weights, and Thyroid Volumes in Present-day Healthy Japanese Volunteers.

Authors:  Takashi Kudo; Akihiro Inano; Sanae Midorikawa; Hitoshi Kubo; Kino Hayashi; Sawako Nakashima; Chizu Fukushima; Kazuya Maeda; Noboru Oriuchi; Shin Irie; Shunichi Yamashita; Hiroyuki Kusuhara
Journal:  Health Phys       Date:  2020-04       Impact factor: 1.316

2.  Absorbed radiation doses in the thyroid as estimated by UNSCEAR and subsequent risk of childhood thyroid cancer following the Great East Japan Earthquake.

Authors:  Tetsuya Ohira; Hiroki Shimura; Fumikazu Hayashi; Masanori Nagao; Seiji Yasumura; Hideto Takahashi; Satoru Suzuki; Takashi Matsuzuka; Satoshi Suzuki; Manabu Iwadate; Tetsuo Ishikawa; Akira Sakai; Shinichi Suzuki; Kenneth E Nollet; Susumu Yokoya; Hitoshi Ohto; Kenji Kamiya
Journal:  J Radiat Res       Date:  2020-03-23       Impact factor: 2.724

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.