Assessment of noise levels in the intensive care unit using Apple Watch.

Tommaso Scquizzato1,2, Arianna Gazzato3, Giovanni Landoni3,4, Alberto Zangrillo3,4.   

Abstract

Entities:  

Mesh:

Year:  2020        PMID: 32252794      PMCID: PMC7137522          DOI: 10.1186/s13054-020-02852-3

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.
Alarms from monitors, medical devices and staff activities increase noise levels in the Intensive Care Unit (ICU) and may disrupt sleep patterns [1] contributing to the development of delirium and post-intensive care syndrome [2]. The World Health Organization (WHO) recommend that hospital noise levels should not exceed 35 A-weighted decibels (dBA) during the day and 30 dBA at night [3]. However, daytime noise levels in ICU were found of around 60 dBA [4]. Apple Watch (Series 4 and 5) takes advantage of the internal microphone to regularly sample sound levels in the environment and might play a role in monitoring noise in the ICU. We investigated the feasibility of analyzing data from an Apple Watch to measure noise levels in the ICU. Accordingly, we exported Health data from the personal Apple Watch of a nurse working in a 14 beds referral cardiothoracic ICU managing patients after cardiac surgery and those with cardiogenic shock, refractory cardiac arrest, and respiratory failure. Noise levels were compared between daytime (7 a.m. - 11 p.m.) and night-time (11 p.m. - 7 a.m.). Data extraction and statistical analysis were performed with the “Pandas” Python Library. An open-source Jupyter notebook has been made available together with this publication on GitHub (https://github.com/tscquizzato/ICU-Noise-Levels-Apple-Watch) with a step-by-step guide to repeat our experience. Consecutive 1086 samples measured during 48 shifts (48% from 7 a.m. to 7:30 p.m. and 52% from 7:15 p.m. to 7:15 a.m.) between November 1, 2019 and February 29, 2020 were extracted. The average sound level was 66 ± 6.1 dBA (Fig. 1). Sound levels significantly differed between daytime and night-time (67 ± 6.7 dBA vs. 64 ± 4.2 dBA, p < 0.001) (Fig. 2). The highest sound level was 89 dBA and was recorded on Monday between 12 a.m. and 1 p.m. The lowest one was 31 dBA between 3 p.m. and 4 p.m. on Sunday. In only 2.8% of samples, noise levels during daytime were below 35 dBA. During the night, sound levels were always above 30 dBA.
Fig. 1

Trend of average sound pressure levels over the 24 h. Values in A-weighted decibels (dBA) are expressed as mean with standard deviation

Fig. 2

Boxplot comparing sound pressure levels during daytime (7 am – 11 pm) and night-time (11 pm – 7 am)

Trend of average sound pressure levels over the 24 h. Values in A-weighted decibels (dBA) are expressed as mean with standard deviation Boxplot comparing sound pressure levels during daytime (7 am – 11 pm) and night-time (11 pm – 7 am) The analysis of noise levels in the ICU using an Apple Watch is feasible and easy to perform. Overall, noise levels were almost always above the recommended values, consistent with previously published studies [4]. The role of wearable devices to measure noise levels deserves to be further investigated. Such devices might also be worn by patients to accurately quantify noise levels and compare with sleep quality and recovery.
  5 in total

1.  The Implication of Physically Demanding and Hazardous Work on Retirement Timing.

Authors:  Johanna Stengård; Marianna Virtanen; Constanze Leineweber; Hugo Westerlund; Hui-Xin Wang
Journal:  Int J Environ Res Public Health       Date:  2022-07-01       Impact factor: 4.614

2.  Influence of noise manipulation on retention in a simulated ICU ward round: an experimental pilot study.

Authors:  Katja Erne; Samuel E J Knobel; Tobias Nef; Marie-Madlen Jeitziner; Aileen C Naef; Stephan M Gerber; Tim Fischer; Fred W Mast; Joerg C Schefold; Bjoern Zante
Journal:  Intensive Care Med Exp       Date:  2022-01-28

3.  Evaluation of noise levels in COVID-19 and non-COVID-19 intensive care units in Italy.

Authors:  Guglielmo Imbriaco; Arianna Gazzato; Alessandro Monesi; Tommaso Scquizzato; Federico Semeraro
Journal:  Intensive Crit Care Nurs       Date:  2021-10-29       Impact factor: 3.072

4.  Acoustic environments of intensive care units during the COVID-19 pandemic.

Authors:  Ziwei Song; Pyoung-Jik Lee; Thomas Hampton
Journal:  Appl Acoust       Date:  2022-09-19       Impact factor: 3.614

5.  Do We Have Measures to Reduce Post-operative Cognitive Dysfunction?

Authors:  Thaddee Valdelievre; Zhiyi Zuo
Journal:  Front Neurosci       Date:  2022-06-02       Impact factor: 5.152

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.