Literature DB >> 3225268

A simulation of rat edl force output based on intrinsic muscle properties.

G J van Ingen Schenau1, M F Bobbert, G J Ettema, J B de Graaf, P A Huijing.   

Abstract

Force-velocity and force-length relations were obtained for the edl of four Wistar rats in order to characterise the contractile properties (CE) of these muscle-tendon complexes. Compliances of the undamped part of the series components (SE) were measured in quick length decreases. Force-extension relations of SEs were obtained by integration of compliance to force. A muscle model consisting of CE, SE and a visco-elastic element was used to simulate the force output of the muscle tendon complex in response to a changing muscle length lOI as input. This simulated force was compared with the experimental force of the same muscle measured in response to the same lOI as input. Tetanic contractions were used in all experiments. The results show that this muscle model can predict the experimental force within a mean maximal error not larger than approximately 14% of the force amplitude. However the comparison of simulated force with experimental force and a few additional experiments show that the muscles do not have a unique instantaneous force-velocity characteristic. As shown by several other studies, force seems to be influenced by many other variables (time, history etc.) than CE length and velocity.

Entities:  

Mesh:

Year:  1988        PMID: 3225268     DOI: 10.1016/0021-9290(88)90014-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  A new model for calculating muscle forces from electromyograms.

Authors:  L J van Ruijven; W A Weijs
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

Review 2.  Validation of Hill-type muscle models in relation to neuromuscular recruitment and force-velocity properties: predicting patterns of in vivo muscle force.

Authors:  Andrew A Biewener; James M Wakeling; Sabrina S Lee; Allison S Arnold
Journal:  Integr Comp Biol       Date:  2014-06-12       Impact factor: 3.326

3.  Accuracy of gastrocnemius muscles forces in walking and running goats predicted by one-element and two-element Hill-type models.

Authors:  Sabrina S M Lee; Allison S Arnold; Maria de Boef Miara; Andrew A Biewener; James M Wakeling
Journal:  J Biomech       Date:  2013-07-18       Impact factor: 2.712

4.  Modeling the chemoelectromechanical behavior of skeletal muscle using the parallel open-source software library OpenCMISS.

Authors:  Thomas Heidlauf; Oliver Röhrle
Journal:  Comput Math Methods Med       Date:  2013-11-17       Impact factor: 2.238

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.