Literature DB >> 32250492

Isotropic 3D Cartesian single breath-hold CINE MRI with multi-bin patch-based low-rank reconstruction.

Thomas Küstner1, Aurelien Bustin1, Olivier Jaubert1, Reza Hajhosseiny1, Pier Giorgio Masci1, Radhouene Neji1,2, René Botnar1,3, Claudia Prieto1,3.   

Abstract

PURPOSE: To develop a novel acquisition and reconstruction framework for isotropic 3D Cartesian cardiac CINE within a single breath-hold for left ventricle (LV) and whole-heart coverage.
METHODS: A variable-density Cartesian acquisition with spiral profile ordering, out-inward sampling, and acquisition-adaptive alternating tiny golden/golden angle increment between spiral arms is proposed to provide incoherent and nonredundant sampling within and among cardiac phases. A novel multi-bin patch-based low-rank reconstruction, named MB-PROST, is proposed to exploit redundant information on a local (within a patch), nonlocal (similar patches within a spatial neighborhood), and temporal (among all cardiac phases) scale with an implicit motion alignment among patches. The proposed multi-bin patch-based low-rank reconstruction reconstruction is compared against compressed sensing reconstruction, whereas LV function parameters derived from the proposed 3D CINE framework are compared against those estimated from conventional multislice 2D CINE imaging in 10 healthy subjects and 15 patients.
RESULTS: The proposed framework provides 3D cardiac CINE images with high spatial (1.9 mm3 ) and temporal resolution (˜50 ms) in a single breath-hold of ˜20 s for LV and ˜26 s for whole-heart coverage in healthy subjects. Shorter breath-hold durations of ˜13 to 15 s are feasible for LV coverage with slightly anisotropic resolution (1.9 × 1.9 × 2.5 mm) in patients. LV function parameters derived from 3D CINE were in good agreement with 2D CINE, with a bias of -0.1 mL/0.1 mL, -0.9 mL/-1.0 mL, -0.1%/-0.8%; and confidence intervals of ±1.7 mL/±3.7 mL, ±1.2 mL/±2.6 mL, and ±1.2%/±3.6% (10 healthy subjects/15 patients) for end-systolic volume, end-diastolic volume, and ejection fraction, respectively.
CONCLUSION: The proposed framework enables 3D isotropic cardiac CINE in a single breath-hold scan of ˜20 s/˜26 s for LV/whole-heart coverage, showing good agreement with clinical 2D CINE scans in terms of LV functional assessment.
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  3D CINE; Cartesian; bSSFP; cardiovascular imaging; low-rank reconstruction; temporal redundancy; whole-heart

Mesh:

Year:  2020        PMID: 32250492     DOI: 10.1002/mrm.28267

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  Cardiac MR: From Theory to Practice.

Authors:  Tevfik F Ismail; Wendy Strugnell; Chiara Coletti; Maša Božić-Iven; Sebastian Weingärtner; Kerstin Hammernik; Teresa Correia; Thomas Küstner
Journal:  Front Cardiovasc Med       Date:  2022-03-03

2.  Three-dimensional simultaneous brain mapping of T1, T2, T2 and magnetic susceptibility with MR Multitasking.

Authors:  Tianle Cao; Sen Ma; Nan Wang; Sara Gharabaghi; Yibin Xie; Zhaoyang Fan; Elliot Hogg; Chaowei Wu; Fei Han; Michele Tagliati; E Mark Haacke; Anthony G Christodoulou; Debiao Li
Journal:  Magn Reson Med       Date:  2021-10-27       Impact factor: 3.737

3.  A completely automated pipeline for 3D reconstruction of human heart from 2D cine magnetic resonance slices.

Authors:  Abhirup Banerjee; Julià Camps; Ernesto Zacur; Christopher M Andrews; Yoram Rudy; Robin P Choudhury; Blanca Rodriguez; Vicente Grau
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-10-25       Impact factor: 4.226

4.  CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions.

Authors:  Thomas Küstner; Niccolo Fuin; Kerstin Hammernik; Aurelien Bustin; Haikun Qi; Reza Hajhosseiny; Pier Giorgio Masci; Radhouene Neji; Daniel Rueckert; René M Botnar; Claudia Prieto
Journal:  Sci Rep       Date:  2020-08-13       Impact factor: 4.379

  4 in total