Literature DB >> 32249256

Structural Valve Deterioration after Transcatheter Aortic Valve Implantation Using J-Valve: A Long-Term Follow-Up.

Fei Li1, Xu Wang1, Yuetang Wang1, Fei Xu2, Xin Wang2, Xuan Li1, Wei Wang1.   

Abstract

PURPOSE: Our study aimed to investigate the structural valve deterioration (SVD) after transcatheter aortic valve implantation (TAVI) using J-Valve.
METHODS: In all, 14 patients with aortic stenosis (AS) and 4 patients with pure aortic regurgitation (PAR) were available in the study. Four-year follow-up was performed in all patients, and the clinical data and echocardiographic findings were recorded and analyzed.
RESULTS: All patients survived at the 4-year follow-up. There was no evidence of morphological SVD or prosthetic valve thrombosis in enrolled patients. None of the hemodynamic SVD occurred in patients with PAR. Mean gradients decreased from 61.93 ± 15.42 mm Hg (pre-TAVI) to 19.64 ± 9.16 mm Hg (discharge) in patients with AS (p <0.001); subsequently, a slight increase was observed in the mean trans-aortic gradient throughout follow-up (p = 0.967). Overall, in patients with AS, six individuals suffered moderate (3/14, 21.4%) or severe (3/14, 21.4%) hemodynamic SVD at 4-year follow-up.
CONCLUSIONS: The limited number of cases provides a preliminary indication of the long-term efficacy of TAVI using J-Valve in patients with PAR. In patients with AS, although the higher rate of SVD was observed, the overall transcatheter heart valve (THV) hemodynamics remained stable over time after prosthetic valve implantation and the long-term durability of J-Valve was convincing.

Entities:  

Keywords:  aortic stenosis; bicuspid aortic valve; pure aortic regurgitation; structural valve deterioration; transcatheter aortic valve implantation

Mesh:

Year:  2020        PMID: 32249256      PMCID: PMC7303316          DOI: 10.5761/atcs.oa.19-00325

Source DB:  PubMed          Journal:  Ann Thorac Cardiovasc Surg        ISSN: 1341-1098            Impact factor:   1.520


  20 in total

1.  Five-Year Clinical Outcome and Valve Durability After Transcatheter Aortic Valve Replacement in High-Risk Patients.

Authors:  Romain Didier; Hélène Eltchaninoff; Patrick Donzeau-Gouge; Karine Chevreul; Jean Fajadet; Pascal Leprince; Alain Leguerrier; Michel Lièvre; Alain Prat; Emmanuel Teiger; Thierry Lefevre; Didier Tchetché; Didier Carrié; Dominique Himbert; Bernard Albat; Alain Cribier; Arnaud Sudre; Didier Blanchard; Gilles Rioufol; Frederic Collet; Remi Houel; Pierre Dos Santos; Nicolas Meneveau; Said Ghostine; Thibaut Manigold; Philippe Guyon; Thomas Cuisset; Herve Le Breton; Stephane Delepine; Xavier Favereau; Geraud Souteyrand; Patrick Ohlmann; Vincent Doisy; Thérèse Lognoné; Antoine Gommeaux; Jean-Philippe Claudel; Francois Bourlon; Bernard Bertrand; Bernard Iung; Martine Gilard
Journal:  Circulation       Date:  2018-12-04       Impact factor: 29.690

2.  Urgent transcatheter aortic valve replacement for severe acute aortic regurgitation following open mitral valve surgery.

Authors:  Roberto Spina; Omar Khalique; Susheel Kodali; Vinayak N Bapat
Journal:  Catheter Cardiovasc Interv       Date:  2018-11-08       Impact factor: 2.692

3.  A versatile transapical device for aortic valvular disease: One-year outcomes of a multicenter study on the J-Valve system.

Authors:  Mingwui Tung; Xu Wang; Fei Li; Hao Wang; Yingqiang Guo; Chunsheng Wang; Lai Wei; Xinjin Luo; Xin Wang; Wei Wang
Journal:  J Cardiol       Date:  2018-07-29       Impact factor: 3.159

4.  Initial German experience with transapical implantation of a second-generation transcatheter heart valve for the treatment of aortic regurgitation.

Authors:  Moritz Seiffert; Ralf Bader; Utz Kappert; Ardawan Rastan; Stephan Krapf; Sabine Bleiziffer; Steffen Hofmann; Martin Arnold; Klaus Kallenbach; Lenard Conradi; Friederike Schlingloff; Manuel Wilbring; Ulrich Schäfer; Patrick Diemert; Hendrik Treede
Journal:  JACC Cardiovasc Interv       Date:  2014-08-13       Impact factor: 11.195

5.  The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation.

Authors:  Miriam Silaschi; Lenard Conradi; Olaf Wendler; Friederike Schlingloff; Utz Kappert; Ardawan J Rastan; Hardy Baumbach; David Holzhey; Walter Eichinger; Ralf Bader; Hendrik Treede
Journal:  Catheter Cardiovasc Interv       Date:  2017-11-24       Impact factor: 2.692

6.  Transfemoral aortic valve implantation in pure native aortic valve insufficiency using the repositionable and retrievable lotus valve.

Authors:  Jochen Wöhrle; Christoph Rodewald; Wolfgang Rottbauer
Journal:  Catheter Cardiovasc Interv       Date:  2015-06-23       Impact factor: 2.692

7.  Assessment of Long-Term Structural Deterioration of Transcatheter Aortic Bioprosthetic Valves Using the New European Definition.

Authors:  Eric Durand; Anastasia Sokoloff; Marina Urena-Alcazar; Bernard Chevalier; Stephan Chassaing; Romain Didier; Christophe Tron; Pierre-Yves Litzler; Claire Bouleti; Dominique Himbert; Thomas Hovasse; Olivier Bar; Guillaume Avinée; Bernard Iung; Didier Blanchard; Martine Gilard; Alain Cribier; Thierry Lefevre; Hélène Eltchaninoff
Journal:  Circ Cardiovasc Interv       Date:  2019-04       Impact factor: 6.546

8.  A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease.

Authors:  Bernard Iung; Gabriel Baron; Eric G Butchart; François Delahaye; Christa Gohlke-Bärwolf; Olaf W Levang; Pilar Tornos; Jean-Louis Vanoverschelde; Frank Vermeer; Eric Boersma; Philippe Ravaud; Alec Vahanian
Journal:  Eur Heart J       Date:  2003-07       Impact factor: 29.983

9.  Transfemoral Implantation of a Fully Repositionable and Retrievable Transcatheter Valve for Noncalcified Pure Aortic Regurgitation.

Authors:  Joachim Schofer; Fabian Nietlispach; Klaudija Bijuklic; Antonio Colombo; Fernando Gatto; Federico De Marco; Antonio Mangieri; Lorenz Hansen; Giuseppe Bruschi; Neil Ruparelia; Friedrich-Christian Rieß; Franscesco Maisano; Azeem Latib
Journal:  JACC Cardiovasc Interv       Date:  2015-11-18       Impact factor: 11.195

10.  Long-term durability and haemodynamic performance of a self-expanding transcatheter heart valve beyond five years after implantation: a prospective observational study applying the standardised definitions of structural deterioration and valve failure.

Authors:  Erik W Holy; Julia Kebernik; Mohammad Abdelghani; Simon F Stämpfli; Jens Hellermann; Abdelhakim Allali; Mohamed El-Mawardy; Susanne Sachse; Thomas F Lüscher; Felix C Tanner; Gert Richardt; Mohamed Abdel-Wahab
Journal:  EuroIntervention       Date:  2018-07-20       Impact factor: 6.534

View more
  5 in total

1.  Artificial Intelligence-Based Spiral CT 3D Reconstruction in Transcatheter Aortic Valve Implantation.

Authors:  Kunpeng Zhang; Yan Gao; Junwei Lv; Jian Li; Jingli Liu
Journal:  Comput Math Methods Med       Date:  2022-05-04       Impact factor: 2.809

2.  Transapical mitral valve-in-valve implantation for failed bioprosthetic valve using the J-valve system with locator device: early and mid-term outcomes.

Authors:  Kun Liu; Jinglun Shen; Kaisheng Wu; Fei Meng; Shengxun Wang; Shuai Zheng; Haibo Zhang
Journal:  Ann Transl Med       Date:  2022-01

Review 3.  Transcatheter Aortic Valve Implantation for Severe Pure Aortic Regurgitation With Dedicated Devices.

Authors:  Pierluigi Costanzo; Paul Bamborough; Mark Peterson; Djeven J Deva; Geraldine Ong; Neil Fam
Journal:  Interv Cardiol       Date:  2022-07-21

4.  Next-generation transcatheter aortic valve implantation.

Authors:  Hong-Gook Lim; Saeromi Jeong; Gi Beom Kim; Whal Lee; Kuk Hui Son; Yong Jin Kim
Journal:  JTCVS Open       Date:  2020-06-24

Review 5.  Transcatheter Aortic Valve Implantation for Pure Native Aortic Regurgitation: The Last Frontier.

Authors:  Ana Paula Tagliari; Rodrigo Petersen Saadi; Eduardo Keller Saadi
Journal:  J Clin Med       Date:  2022-09-01       Impact factor: 4.964

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.