Stroke rate after endovascular aortic interventions in the Society for Vascular Surgery Vascular Quality Initiative.

Nicholas J Swerdlow1, Patric Liang1, Chun Li1, Kirsten Dansey1, Thomas F X O'Donnell2, Livia E V M de Guerre1, Rens R B Varkevisser1, Virendra I Patel3, Grace J Wang4, Marc L Schermerhorn5.   

Abstract

OBJECTIVE: The stroke rate after endovascular aneurysm repair (EVAR), particularly complex EVAR such as fenestrated EVAR (FEVAR) and chimney EVAR (chEVAR), is not well defined. Whereas stroke is a well-established risk of thoracic endovascular aortic repair (TEVAR), the impact of procedural characteristics on stroke remains unclear. Therefore, we characterized the risk of stroke after endovascular aortic interventions in the Vascular Quality Initiative database and identified procedural characteristics associated with stroke.
METHODS: We performed a retrospective cohort study of patients undergoing infrarenal EVAR, complex EVAR, and TEVAR within the Vascular Quality Initiative between 2011 and 2019. Complex EVAR included FEVAR (with either a Food and Drug Administration-approved custom-manufactured device or physician-modified endovascular graft) and chEVAR. We excluded emergent procedures. The primary outcome was in-hospital stroke. We used multivariable logistic regression to identify procedural characteristics associated with stroke.
RESULTS: We identified 41,540 EVARs, 1371 complex EVARs, and 4600 TEVARs. The in-hospital stroke rate was 0.1% after EVAR, 0.9% after complex EVAR, and 2.9% after TEVAR. In patients undergoing EVAR, aneurysm diameter >6.5 mm (odds ratio [OR], 1.7; 95% confidence interval [CI], 1.1-2.7; P = .03) and use of a proximal extension cuff (OR, 3.3; 95% CI, 1.4-7.9; P < .01) were independently associated with stroke. Among complex EVARs, stroke rate was 0.7% after FEVAR with a custom-manufactured device, 0.4% after FEVAR with a physician-modified endovascular graft, and 2.1% after chEVAR (P = .08). In multivariable analysis, arm access was associated with 8.4-fold higher odds of stroke (95% CI, 1.7-41; P < .01). Whereas chEVAR was associated with higher odds of stroke in crude analysis, this association did not persist after adjustment for arm access (OR, 1.0; 95% CI, 0.2-4.4; P = .99). In patients undergoing TEVAR, more proximal landing zones were associated with higher risk of stroke compared with zone 4/5 (zone 3: OR, 2.0 [95% CI, 0.9-4.2]; zone 2: OR, 3.8 [95% CI, 1.8-8.2]; zone 0/1: OR, 6.3 [95% CI, 2.8-14]). In terms of procedural characteristics, any involvement of the left subclavian artery was associated with stroke (bypass: OR, 2.5 [95% CI, 1.5-4.0]; stent: OR, 2.7 [95% CI, 0.9-8.5]; covered or occluded: OR, 2.5 [95% CI, 1.5-4.1]).
CONCLUSIONS: Stroke, although rare after elective EVAR, is substantially more common after complex EVAR and TEVAR. Increasing procedural complexity in complex EVAR and TEVAR is associated with a higher stroke rate, a risk that should be factored into clinical decision-making. The strong association between stroke and upper extremity access during complex EVAR is alarming and warrants further study.
Copyright © 2020 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aortic aneurysm; Endovascular procedures; Stroke

Year:  2020        PMID: 32249044     DOI: 10.1016/j.jvs.2020.02.015

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  3 in total

1.  Primary Stroke and Failure-to-Rescue Following Thoracic Endovascular Aortic Aneurysm Repair.

Authors:  Christian Mpody; Jerry Cui; Hamdy Awad; Sujatha Bhandary; Michael Essandoh; Ronald L Harter; Joseph D Tobias; Olubukola O Nafiu
Journal:  J Cardiothorac Vasc Anesth       Date:  2020-12-02       Impact factor: 2.628

Review 2.  Narrative review on endovascular techniques for left subclavian artery revascularization during thoracic endovascular aortic repair and risk factors for postoperative stroke.

Authors:  Mario D'Oria; Kevin Mani; Randall DeMartino; Martin Czerny; Konstantinos P Donas; Anders Wanhainen; Sandro Lepidi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-10

3.  Use of a Steerable Sheath for Completely Femoral Access in Branched Endovascular Aortic Repair Compared to Upper Extremity Access.

Authors:  Sven R Hauck; Wolf Eilenberg; Alexander Kupferthaler; Maximilian Kern; Theresa-Marie Dachs; Alexander Wressnegger; Christoph Neumayer; Christian Loewe; Martin A Funovics
Journal:  Cardiovasc Intervent Radiol       Date:  2022-04-07       Impact factor: 2.797

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.