Literature DB >> 32237003

Cardiac implantable electronic devices in patients with persistent left superior vena cava-A single center experience.

Bahjat Ghazzal1, Dean Sabayon2, Soroosh Kiani3, Angel R Leon3, David Delurgio4, Anshul M Patel3, Michael S Lloyd5, Stacy Westerman3, Anand Shah5, Faisal M Merchant3, Mikhael F El-Chami3.   

Abstract

BACKGROUND: There are limited data on cardiac implantable electronic device implantation (CIED) in patients with persistent left superior vena cava (PLSVC).
OBJECTIVE: To describe the outcomes of implanting CIEDs with a focus on cardiac resynchronization therapy (CRT) in patients with PLSVC.
METHODS: We identified all patients with a PLSVC that underwent CIED implantation from December 2008 until February 2019 at our institution by querying the electronic medical record (n = 34). We then identified controls in a 3:1 fashion (n = 102) by matching on device type (CRT vs non-CRT). Procedure success, complications, fluoroscopy and procedural time were recorded. Outcomes were compared using a two-way analysis of variance test and conditional regression modeling for continuous and categorical variables, respectively.
RESULTS: A total of 34 patients with PLSVC underwent 38 procedures. Four patients underwent dual chamber system implantation followed by a subsequent upgrade to CRT. Thirteen patients underwent CRT implantation: one was implanted via the right subclavian while the rest were implanted via the PLSVC. Left ventricular (P = .06). Procedure and fluoroscopy times were significantly higher in the PLSVC as compared with the control group (97.7 vs 66.1 minute, P < .001 and 18.1 minute vs 8.7 minutes, P = .005, respectively).
CONCLUSION: CIED implant in patients with PLSVC is feasible but technically more challenging and appears to be associated with higher risk of right ventricular lead dislodgment.
© 2020 Wiley Periodicals, Inc.

Entities:  

Keywords:  ICD; cardiac implantable electronic devices; left ventricular lead; pacemakers; persistent left superior vena cava

Mesh:

Year:  2020        PMID: 32237003     DOI: 10.1111/jce.14460

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  1 in total

1.  High defibrillation threshold with right-sided ICD implantation was resolved by a dual coil lead via persistent left superior vena cava.

Authors:  Takefumi Fujito; Daigo Nagahara; Taro Tsuzuki; Naoyuki Kamiyama; Atsushi Mochizuki; Tetsuji Miura
Journal:  J Cardiol Cases       Date:  2021-11-22
  1 in total