Nigel Hacking1, Drew Maclean2, Ganesh Vigneswaran1, Timothy Bryant1, Sachin Modi1. 1. Department of Interventional Radiology, University Hospital Southampton, Tremona Road, Southampton, SO16 6YD, UK. 2. Department of Interventional Radiology, University Hospital Southampton, Tremona Road, Southampton, SO16 6YD, UK. drew.maclean@uhs.nhs.uk.
Abstract
INTRODUCTION: Optisphere (Teleflex, Wayne, PA, USA, currently distributed by Medtronic, Minneapolis, MN, USA) is a new, resorbable, calibrated spherical embolic agent. We aimed to evaluate its clinical safety and effectiveness for fibroid embolization through a prospective case series. METHOD: This prospective case series studied patients treated with fibroid embolization using Optisphere between July 2017 and June 2018. The primary outcomes were device-related adverse event assessments and MRI-determined percentage infarct of the dominant fibroid (DF %) and infarct of all fibroids (AF %) at 3 months post-embolization. Secondary outcomes included symptom improvement with the validated Uterine Fibroid Symptom Score and Quality of Life questionnaire (UFS-SS and UFS-QOL) at 3 months and 12 months post-embolization. Statistical analysis was through the Wilcoxon signed-rank test for nonparametric paired data. RESULTS: Twenty-three consecutive patients were treated with Optisphere (median age 44.0, uterine volume 484.0 ml, dominant fibroid volume 167.0 ml). The complete dominant fibroid infarction (DF %) rate was 91.3% (21/23 patients), and the complete all fibroid infarction rate (AF %) was 82.6% (19/23). No adverse device-related safety events were encountered. Significant improvement was demonstrated in 3-month UFS-SS (56 vs 19, p < 0.0001), UFS-QOL (40 vs 88, p = 0.0008), uterine volume (484 ml vs 246 ml, p < 0.0001) and dominant fibroid volume (167 vs 64 ml, p < 0.0001). Symptomatic improvement continued to 12 months (UFS-SS 56 vs 11, p = 0.0008, UFS-QOL 40 vs 98.7, p = 0.0008). CONCLUSION: Optisphere is an effective embolic agent for fibroid embolization with good symptomatic response and percentage fibroid infarct.
INTRODUCTION: Optisphere (Teleflex, Wayne, PA, USA, currently distributed by Medtronic, Minneapolis, MN, USA) is a new, resorbable, calibrated spherical embolic agent. We aimed to evaluate its clinical safety and effectiveness for fibroid embolization through a prospective case series. METHOD: This prospective case series studied patients treated with fibroid embolization using Optisphere between July 2017 and June 2018. The primary outcomes were device-related adverse event assessments and MRI-determined percentage infarct of the dominant fibroid (DF %) and infarct of all fibroids (AF %) at 3 months post-embolization. Secondary outcomes included symptom improvement with the validated Uterine Fibroid Symptom Score and Quality of Life questionnaire (UFS-SS and UFS-QOL) at 3 months and 12 months post-embolization. Statistical analysis was through the Wilcoxon signed-rank test for nonparametric paired data. RESULTS: Twenty-three consecutive patients were treated with Optisphere (median age 44.0, uterine volume 484.0 ml, dominant fibroid volume 167.0 ml). The complete dominant fibroid infarction (DF %) rate was 91.3% (21/23 patients), and the complete all fibroid infarction rate (AF %) was 82.6% (19/23). No adverse device-related safety events were encountered. Significant improvement was demonstrated in 3-month UFS-SS (56 vs 19, p < 0.0001), UFS-QOL (40 vs 88, p = 0.0008), uterine volume (484 ml vs 246 ml, p < 0.0001) and dominant fibroid volume (167 vs 64 ml, p < 0.0001). Symptomatic improvement continued to 12 months (UFS-SS 56 vs 11, p = 0.0008, UFS-QOL 40 vs 98.7, p = 0.0008). CONCLUSION: Optisphere is an effective embolic agent for fibroid embolization with good symptomatic response and percentage fibroid infarct.