Amelie Bäumer1,2, Shirin Toekan3, Daniel Saure4, Gerd Körner5. 1. Section of Periodontology, Department of Conservative Dentistry, Clinic for Oral, Dental and Maxillofacial Diseases, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. ab@paroplant.com. 2. Private Practice, Niedernstrasse 16, 33602, Bielefeld, Germany. ab@paroplant.com. 3. Private Practice, Dortmund, Germany. 4. Institute of Medical Biometry and Informatics, University of Heidelberg, 69120, Heidelberg, Germany. 5. Private Practice, Niedernstrasse 16, 33602, Bielefeld, Germany.
Abstract
BACKGROUND: To assess long-term results of implants (XiVE/Frialit-2 Synchro) in a private periodontal practice according to survival and success rates (biological and technical complications) and to detect possible influencing factors, retrospectively. METHODS: Implant placement of at least one implant took place 10 years ±6 months before clinical and radiographic re-examination. Incidence of implant loss as main and incidence of mucositis/ peri-implantitis as secondary outcome were detected. Also, patient-related and implant-related influencing factors were determined by regression analyses. RESULTS: 100 patients (59.0% female) with 242 implants were included into analysis. Survival rate was 94.0% (XiVE: 97.7%; Frialit-2-Synchro: 66.7%). Mucositis was found in 77.6% of all patients, moderate/severe peri-implantitis in 16.3%. In logistic regression analyses statistically significant influencing factors for implant loss was implant type (p < 0.001), for mucositis a wider implant diameter (p = 0.0438) and a high modified Plaque Index (p = 0.0253), for peri-implantits number of implants per patient (p = 0.0075) and a wider implant diameter (p = 0.0079). Technical complications were found in 47 implants (19.4%). CONCLUSIONS: XiVE implants showed a high survival rate over a 10-year follow-up, on the other hand Frialit-2 Synchro implants had worse survival rates. Success rates regarding biological complications are in line with other implant systems.
BACKGROUND: To assess long-term results of implants (XiVE/Frialit-2 Synchro) in a private periodontal practice according to survival and success rates (biological and technical complications) and to detect possible influencing factors, retrospectively. METHODS: Implant placement of at least one implant took place 10 years ±6 months before clinical and radiographic re-examination. Incidence of implant loss as main and incidence of mucositis/ peri-implantitis as secondary outcome were detected. Also, patient-related and implant-related influencing factors were determined by regression analyses. RESULTS: 100 patients (59.0% female) with 242 implants were included into analysis. Survival rate was 94.0% (XiVE: 97.7%; Frialit-2-Synchro: 66.7%). Mucositis was found in 77.6% of all patients, moderate/severe peri-implantitis in 16.3%. In logistic regression analyses statistically significant influencing factors for implant loss was implant type (p < 0.001), for mucositis a wider implant diameter (p = 0.0438) and a high modified Plaque Index (p = 0.0253), for peri-implantits number of implants per patient (p = 0.0075) and a wider implant diameter (p = 0.0079). Technical complications were found in 47 implants (19.4%). CONCLUSIONS: XiVE implants showed a high survival rate over a 10-year follow-up, on the other hand Frialit-2 Synchro implants had worse survival rates. Success rates regarding biological complications are in line with other implant systems.
Authors: Pedro Diaz; Esther Gonzalo; Luis J Gil Villagra; Barbara Miegimolle; Maria J Suarez Journal: BMC Oral Health Date: 2022-10-19 Impact factor: 3.747