Literature DB >> 32222901

Improved crossability with novel cutting balloon versus scoring balloon in the treatment of calcified lesion.

Takayuki Ishihara1, Osamu Iida2, Mitsuyoshi Takahara3, Takuya Tsujimura2, Shota Okuno2, Naoya Kurata4, Mitsutoshi Asai2, Shin Okamoto2, Kiyonori Nanto2, Toshiaki Mano2.   

Abstract

Cutting balloons and scoring balloons are commonly used for the preparation of calcified lesion. However, problems with crossability occasionally limit the use of cutting balloons. We prospectively selected 173 calcified lesions treated using a novel cutting balloon (Wolverine™, C group). As control, we retrospectively analyzed 146 calcified lesions treated using a scoring balloon (Lacrosse NSE ALPHA™, S group). Either intravascular ultrasound (IVUS) or optical coherence tomography (OCT) was used by the operator's discretion. The primary outcome was delivery success, which was defined as successful passage to the target lesion immediately after IVUS or OCT evaluation. The secondary outcome was acute cross-sectional area (CSA) gain, which was defined as post-interventional minimum stent area minus pre-procedural minimum lumen area. A multivariate analysis evaluated the independent predictors for delivery success. The delivery success rate was significantly higher in the C group versus the S group (90.8% versus 79.5%, P = 0.006). However, the acute CSA gain was similar between the two groups (IVUS: 3.2 ± 1.8 mm2 versus 3.4 ± 1.9 mm2, P = 0.53; OCT: 3.6 ± 1.4 mm2 versus 4.1 ± 1.9 mm2, P = 0.11). Usage of cutting balloon was an independent predictor for delivery success even after the adjustment for the patient and lesion characteristics [odds ratio (OR): 2.72 (95% confidence interval 1.38-5.33), P = 0.004] as well as the procedural characteristics [OR: 2.34 (1.15-4.86), P = 0.018]. Novel cutting balloons demonstrated better crossability and similar acute CSA gain compared with scoring balloons in calcified lesion.

Entities:  

Keywords:  Calcified lesion; Crossability; Cutting balloon; Scoring balloon

Mesh:

Year:  2020        PMID: 32222901     DOI: 10.1007/s12928-020-00663-5

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


  1 in total

1.  Effect of cutting balloon after rotational atherectomy in severely calcified coronary artery lesions as assessed by optical coherence tomography.

Authors:  Kisaki Amemiya; Myong Hwa Yamamoto; Akiko Maehara; Yuji Oyama; Wataru Igawa; Morio Ono; Takehiko Kido; Seitarou Ebara; Toshitaka Okabe; Kennosuke Yamashita; Koichi Hoshimoto; Shigeo Saito; Tadayuki Yakushiji; Naoei Isomura; Hiroshi Araki; Gary S Mintz; Masahiko Ochiai
Journal:  Catheter Cardiovasc Interv       Date:  2019-04-11       Impact factor: 2.692

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.