Abstract

Static computer-assisted surgery (s-CAS) has been introduced to improve the results of implantology. A prospective cohort study was conducted following the STROBE guidelines to determine the presence of a learning curve in s-CAS. Six partially and six totally edentulous patients were treated by two surgeons experienced in implantology but completely inexperienced in s-CAS. Preoperative and postoperative computed tomography scans were matched to assess coronal, apical, and angular deviation and the positioning error. The accuracy data were used to evaluate the learning curve. Fifty-six implants were inserted. In partially and totally edentulous patients, the mean (range; standard deviation) coronal deviation was 0.87 (0.34-1.27; 0.35) and 1.24 (0.72-2.67; 0.79); the mean apical deviation was 1.13 (0.48-1.63; 0.39) and 1.52 (0.88-3.84; 1.15); the mean angular deviation was 2.63 (1.89-4.50; 0.98) and 3.59 (1.69-6.30; 1.65); and the mean positioning error was 0.80 (0.32-1.25; 0.35) and 1.14 (0.35-2.56; 0.77), respectively. A typical 'learning curve' effect was not identified for s-CAS.
Copyright © 2020 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  accuracy; computer-aided implant surgery; computer-aided implantology; computer-guided implantology; dental implant; learning curve; static computer-assisted surgery

Year:  2020        PMID: 32217033     DOI: 10.1016/j.ijom.2020.03.007

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  7 in total

1.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

2.  Does the macro design of an implant affect the accuracy of template-guided implantation? A prospective clinical study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph
Journal:  Int J Implant Dent       Date:  2021-04-26

3.  A pilot study of a deep learning approach to detect marginal bone loss around implants.

Authors:  Min Liu; Shimin Wang; Hu Chen; Yunsong Liu
Journal:  BMC Oral Health       Date:  2022-01-16       Impact factor: 2.757

4.  CBCT and CAD-CAM technology to design a minimally invasive maxillary expander.

Authors:  Diego Sánchez-Riofrío; María J Viñas; Josep M Ustrell-Torrent
Journal:  BMC Oral Health       Date:  2020-11-04       Impact factor: 2.757

5.  Uprighting Impacted Mandibular Second Molar Using a Skeletal Anchorage: A Case Report.

Authors:  Federica Altieri; Rosanna Guarnieri; Martina Mezio; Gabriella Padalino; Angela Cipollone; Ersilia Barbato; Michele Cassetta
Journal:  Dent J (Basel)       Date:  2020-11-18

6.  Accuracy of Computer-Assisted Dynamic Navigation as a Function of Different Intraoral Reference Systems: An In Vitro Study.

Authors:  Sigmar Schnutenhaus; Anne Knipper; Martin Wetzel; Cornelia Edelmann; Ralph Luthardt
Journal:  Int J Environ Res Public Health       Date:  2021-03-21       Impact factor: 3.390

7.  Computer-Guided Bone Biopsy: A Technical Note with the Description of a Clinical Case.

Authors:  Federica Altieri; Giovanna Iezzi; Valeria Luzzi; Gianni Di Giorgio; Antonella Polimeni; Michele Cassetta
Journal:  Bioengineering (Basel)       Date:  2021-12-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.