Literature DB >> 32217023

Computed tomography-based hemodynamic index for aortic dissection.

Huanming Xu1, Jiang Xiong2, Xiaofeng Han3, Yuqian Mei1, Yue Shi4, Dianpeng Wang5, Mingchen Zhang6, Duanduan Chen7.   

Abstract

OBJECTIVE: In this study we aimed to propose a new computed tomography-based hemodynamic indicator to quantify the functional significance of aortic dissection and predict post intervention luminal remodeling.
METHODS: Computational hemodynamics and 3D structural analyses were conducted in 51 patients with type B aortic dissection, at initial presentation and at approximately 1 month, 3 months, and 1 year post intervention. A functional index was proposed on the basis of luminal pressure difference. Statistical relationships between the proposed indicator and longitudinal luminal development were analyzed.
RESULTS: The computed luminal pressure difference (true lumen pressure minus false lumen pressure) varied overall from positive to negative along the aorta. The first balance position at which the pressure difference equals 0 was proposed as the functional indicator. A more distally located first balance position indicated better functional status. Implantation of stent graft distally shifted this balance position. Patients with the balance position shifted out of the dissected region (43%) presented the highest functional improvement after intervention; whereas those with the balance position shifted to the abdominal region (25%) showed unsatisfactory results. The magnitude of distal shifting of the first balance position at 3 months post intervention was statistically related to the subsequent true lumen expansion and false lumen reduction.
CONCLUSIONS: The first balance position of luminal pressure difference quantified the hemodynamic status of the dissected aorta. The magnitude of distal shifting of the balance position after intervention was associated with functional improvement and might be used predict longitudinal aortic remodeling.
Copyright © 2020 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  aortic dissection; aortic remodeling; functional index; hemodynamics; thoracic endovascular aortic repair

Mesh:

Year:  2020        PMID: 32217023     DOI: 10.1016/j.jtcvs.2020.02.034

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  5 in total

1.  Functional Evaluation of Embedded Modular Single-Branched Stent Graft: Application to Type B Aortic Dissection With Aberrant Right Subclavian Artery.

Authors:  Xuehuan Zhang; Duanduan Chen; Mingwei Wu; Huiwu Dong; Zhengdong Wan; Heyue Jia; Shichao Liang; Jun Shao; Jun Zheng; Shangdong Xu; Jiang Xiong; Wei Guo
Journal:  Front Cardiovasc Med       Date:  2022-05-02

2.  In-vitro and In-silico Haemodynamic Analyses of a Novel Embedded Iliac Branch Device.

Authors:  Shichao Liang; Heyue Jia; Xuehuan Zhang; Wei Guo; Guojing Zhou; Shilong Li; Panpan Yuan; Jiang Xiong; Duanduan Chen
Journal:  Front Cardiovasc Med       Date:  2022-04-05

3.  The Necessity to Seal the Re-Entry Tears of Aortic Dissection After TEVAR: A Hemodynamic Indicator.

Authors:  Zhenfeng Li; Huanming Xu; Chlöe Harriet Armour; Yuze Guo; Jiang Xiong; Xiaoyun Xu; Duanduan Chen
Journal:  Front Bioeng Biotechnol       Date:  2022-03-31

4.  Clinical Results and Aortic Remodeling After Endovascular Treatment for Complicated Type B Aortic Dissection With the "Fabulous" Stent System.

Authors:  Ruihan Wang; Yuanqing Kan; Mou Yang; Hongkun Zhang; Xiaoming Zhang; Xiangchen Dai; Shuiting Zhai; Hejie Hu; Xiwei Zhang; Bing Chen; Jianhua Huang; Xiao Qin; Zhanxiang Xiao; Xinwu Lu; Wei Guo; Yi Si; Weiguo Fu
Journal:  Front Cardiovasc Med       Date:  2022-02-14

5.  Is Partially Thrombosed False Lumen Really a Predictor for Adverse Events in Uncomplicated Type B Aortic Dissection: A Systematic Review and Meta-Analysis?

Authors:  Jinlin Wu; Jian Song; Xin Li; Jue Yang; Changjiang Yu; Chenyu Zhou; Tucheng Sun; Ruixin Fan
Journal:  Front Cardiovasc Med       Date:  2022-01-18
  5 in total