Literature DB >> 32213497

Ultrasound Doppler and tenosynovial fluid analysis in tenosynovitis.

Fawad Aslam1, Bryant R England2,3, Amy Cannella4, Veronika Sharp5, Lily Kao6, Jon Arnason7, Jemima Albayda8, Catherine Bakewell9, Shruti Sanghvi9, Robert Fairchild10, Karina D Torralba11, Amy Evangelisto12, Paul J DeMarco13,14, Narandra Bethina15, Eugene Y Kissin16.   

Abstract

OBJECTIVE: To assess Doppler ultrasound (US) and tenosynovial fluid (TSF) characteristics in tenosynovitis within common rheumatic conditions, as well as their diagnostic utility.
METHODS: Subjects with tenosynovitis underwent Doppler US and US-guided TSF aspiration for white cell count (WCC) and crystal analysis. Tenosynovial Doppler scores (DS) were semiquantitatively graded. TSF WCC and DS were compared using Kruskal-Wallis tests and logistic regression between non-inflammatory conditions (NIC), inflammatory conditions (IC) and crystal-related conditions (CRC). Receiver operating curves, sensitivity and specificity assessed the ability of WCC and DS to discriminate IC from NIC.
RESULTS: We analysed 100 subjects from 14 sites. The mean age was 62 years, 65% were female, and the mean TSF volume was 1.2 mL. Doppler signal was present in 93.7% of the IC group and was more frequent in IC than in NIC group (OR 6.82, 95% CI 1.41 to 32.97). The TSF median WCC per 109/L was significantly higher in the IC (2.58, p<0.001) and CRC (1.07, p<0.01) groups versus the NIC group (0.38). A TSF cut-off of ≥0.67 WCC per 109/L optimally discriminated IC versus NIC with a sensitivity and specificity each of 81.3%. In the IC group, 20 of 48 (41.7%) subjects had a TSF WCC <2.00 per 109/L.
CONCLUSIONS: A negative DS helps rule out IC in tenosynovitis, but a positive DS is non-specific and merits TSF testing. Unlike synovial fluid, a lower TSF WCC better discriminates IC from NIC. US guidance facilitates aspiration of minute TSF volume, which is critical for diagnosing tenosynovial CRC. © Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  arthritis; synovial fluid; ultrasonography

Year:  2020        PMID: 32213497     DOI: 10.1136/annrheumdis-2020-216927

Source DB:  PubMed          Journal:  Ann Rheum Dis        ISSN: 0003-4967            Impact factor:   19.103


  1 in total

1.  Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures.

Authors:  Emirhan Usta; Ahmet O Akpolat; Ahmet N Kahraman; Adnan Kara; Yunus Oc; Bekir E Kilinc
Journal:  Cureus       Date:  2022-06-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.