Literature DB >> 32213465

A green and low-cost method employing switchable hydrophilicity solvent for the simultaneous determination of antidepressants in human urine by gas chromatography - mass spectrometry detection.

Anderson Luiz Oenning1, Letícia Birk2, Sarah Eller2, Tiago Franco de Oliveira2, Josias Merib3, Eduardo Carasek4.   

Abstract

In this study, the use of switchable hydrophilicity solvent with a simple and low-cost lab-made device for the extraction procedure in homogeneous liquid-liquid microextraction is proposed for the first time in the determination of antidepressants in human urine. The antidepressants studied consisted of fluoxetine, amitriptyline, nortriptyline, imipramine, desipramine and sertraline. The optimization of the main parameters that can influence on the extraction efficiency was performed through multivariate approaches. The analytes were separated and identified by gas chromatography coupled to mass spectrometry (GC-MS). The optimal extraction conditions consisted of using N,N-dimethylcyclohexylamine (DMCHA) as the switchable hydrophilicity solvent (SHS), 500 µL of urine sample previously diluted with ultrapure water at 1:1 ratio (v/v), 200 μL of a mixture of SHS:HCl 6 mol L-1 (1:1 v/v), 600 μL of NaOH 10 mol L-1 and 3 min of extraction time. A volume of 40 µL of diphenylamine at concentration of 500 µg L-1 (20 ng) was used as internal standard. The method developed was in-house validated, providing coefficients of determination higher than 0.995 for all analytes, limits of detection (LOD) from 0.02 to 0.88 µg L-1, limits of quantification (LOQ) from 0.05 to 2.92 µg L-1, relative recoveries of 68 to 102%, intra-day precision from 0.5 to 15.9%, inter-day precision from 4.2 to 19.3%, selectivity and robustness. The method proposed was successfully applied in five human urine samples from a Toxicological Information Center located in Porto Alegre (Brazil). The results demonstrated that the µP-SHS-HLLME approach is highly cost-effective, rapid, simple and environmentally-friendly with satisfactory analytical performance.
Copyright © 2020. Published by Elsevier B.V.

Entities:  

Keywords:  Antidepressants; GC-MS; Homogeneous liquid-liquid microextraction; Switchable hydrophilicity solvents; Urine

Year:  2020        PMID: 32213465     DOI: 10.1016/j.jchromb.2020.122069

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

Review 1.  Low-cost and open-source strategies for chemical separations.

Authors:  Joshua J Davis; Samuel W Foster; James P Grinias
Journal:  J Chromatogr A       Date:  2020-12-24       Impact factor: 4.759

2.  Polydopamine coated hypodermic needles as a microextraction device for the determination of tricyclic antidepressants in oral fluid by direct infusion MS/MS.

Authors:  Carmina Vejar-Vivar; María Teresa García-Valverde; Claudia Mardones; Rafael Lucena; Soledad Cárdenas
Journal:  RSC Adv       Date:  2021-06-28       Impact factor: 3.361

3.  New Method for the Monitoring of Antidepressants in Oral Fluid Using Dried Spot Sampling.

Authors:  Sofia Soares; Tiago Rosado; Mário Barroso; Eugenia Gallardo
Journal:  Pharmaceuticals (Basel)       Date:  2021-12-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.