Literature DB >> 32209342

Ratio of Axial Length to Corneal Radius in Japanese Patients and Accuracy of Intraocular Lens Power Calculation Based on Biometric Data.

Miki Kamikawatoko Omoto1, Hidemasa Torii1, Ken Hayashi2, Masahiko Ayaki3, Kazuo Tsubota1, Kazuno Negishi4.   

Abstract

PURPOSE: To evaluate the features of the axial length-to-corneal radius (AL/CR) ratio in Japanese patients with cataracts and to determine the accuracy of intraocular lens (IOL) power calculation formulas according to the AL/CR features and the axial length (AL).
DESIGN: Retrospective observational case series.
METHODS: Setting was a clinical practice. Patient population was a total of 1,135 eyes (1,135 patients) with cataracts. Observation procedures included measurement of the AL and corenal radius (CR) by optical biometry and evaluation of the refractive outcomes by using the SRK/T, Holladay 1, Hoffer Q, Haigis, and Barrett Universal II formulas. Main outcome measurements were the features of the AL/CR ratio and the accuracy of IOL power calculations based on the AL/CR ratio and the AL.
RESULTS: The mean AL/CR ratio was 3.15 ± 0.19. Significant weak negative correlations were observed between the spherical equivalent (SE) and AL (r = -0.7489; P < .001) and between the SE and AL/CR ratio (r = -0.8069; P < .001); no correlation was found between the SE and CR (r = 0.0208, P = .483). For medium ALs and high AL/CR ratios, the SRK/T formula performed less accurately. For long ALs and high AL/CR ratios, the Holladay 1 and Hoffer Q formulas performed less accurately. The Barrett Universal II formula performed well across a range of ALs and AL/CR ratios.
CONCLUSIONS: The AL/CR ratio explained the total variation in the SE better than the AL alone. Surgeons should pay attention to the selection of IOL power calculation formulas in eyes with high AL/CR ratios.
Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 32209342     DOI: 10.1016/j.ajo.2020.03.006

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  4 in total

1.  Accuracy of new-generation intraocular lens calculation formulas in eyes with variations in predicted refraction.

Authors:  Pingjun Chang; Shuyi Qian; Yalan Wang; Siyan Li; Fuman Yang; Yiwen Hu; Zhuohan Liu; Yun-E Zhao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-08       Impact factor: 3.117

2.  Algorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length.

Authors:  Jung Wan Kim; Youngsub Eom; Eun Gyu Yoon; Young Choi; Jong Suk Song; Ji Won Jeong; Seh Kwang Park; Hyo Myung Kim
Journal:  Acta Ophthalmol       Date:  2021-08-11       Impact factor: 3.988

3.  Investigating the Prediction Accuracy of Recently Updated Intraocular Lens Power Formulas with Artificial Intelligence for High Myopia.

Authors:  Miki Omoto; Kaoruko Sugawara; Hidemasa Torii; Erisa Yotsukura; Sachiko Masui; Yuta Shigeno; Yasuyo Nishi; Kazuno Negishi
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

4.  Accuracy of the Barrett Universal II formula integrated into a commercially available optical biometer when using a preloaded single-piece intraocular lens.

Authors:  Hiroki Mieno; Osamu Hieda; Toshihide Ikeda; Shino Hayashi; Masatsugu Hashida; Kimiaki Urabe; Chie Sotozono
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.