Literature DB >> 32206390

Vector magnetocardiography measurement with a compact elliptically polarized laser-pumped magnetometer.

Wenqiang Zheng1, Shengran Su1, Guoyi Zhang1, Xin Bi1, Qiang Lin1.   

Abstract

We report on a practical approach to vector biomagnetism measurement with an optically pumped magnetometer for measuring total magnetic field intensity. Its application to vector magnetocardiography is experimentally demonstrated with a compact elliptically polarized laser-pumped M x atomic magnetometer (EPMx OPM). The approach is proved to be effective and able to provide more complete cardiac magnetic information. The cardiac magnetic vectors are displayed in three-dimensional space in the form of magnetic vector loops. The sensor configuration and the image processing method here are expected to form further values, especially for multi-channel vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.
© 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Year:  2020        PMID: 32206390      PMCID: PMC7041466          DOI: 10.1364/BOE.380314

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  20 in total

1.  The human vector magnetogastrogram and magnetoenterogram.

Authors:  L A Bradshaw; J K Ladipo; D J Staton; J P Wikswo; W O Richards
Journal:  IEEE Trans Biomed Eng       Date:  1999-08       Impact factor: 4.538

2.  DETECTION OF THE MAGNETIC FIELD OF THE HEART.

Authors:  G BAULE; R MCFEE
Journal:  Am Heart J       Date:  1963-07       Impact factor: 4.749

3.  Spatial distribution of cardiac magnetic vector fields acquired from 3120 SQUID positions.

Authors:  U Steinhoff; A Schnabel; M Burghoff; T Freibier; F Thiel; H Koch; L Trahms
Journal:  Neurol Clin Neurophysiol       Date:  2004-11-30

4.  Clinical application of magnetocardiography.

Authors:  Riccardo Fenici; Donatella Brisinda; Anna Maria Meloni
Journal:  Expert Rev Mol Diagn       Date:  2005-05       Impact factor: 5.225

5.  Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model.

Authors:  Ville Mäntynen; Teijo Konttila; Matti Stenroos
Journal:  Phys Med Biol       Date:  2014-11-03       Impact factor: 3.609

6.  All-optical vector atomic magnetometer.

Authors:  B Patton; E Zhivun; D C Hovde; D Budker
Journal:  Phys Rev Lett       Date:  2014-07-01       Impact factor: 9.161

7.  Optical multichannel room temperature magnetic field imaging system for clinical application.

Authors:  G Lembke; S N Erné; H Nowak; B Menhorn; A Pasquarelli
Journal:  Biomed Opt Express       Date:  2014-02-25       Impact factor: 3.732

8.  Elliptically polarized laser-pumped Mx magnetometer towards applications at room temperature.

Authors:  Shengran Su; Guoyi Zhang; Xin Bi; Xiang He; Wenqiang Zheng; Qiang Lin
Journal:  Opt Express       Date:  2019-11-11       Impact factor: 3.894

9.  Measurement of the human magnetic heart vector.

Authors:  W H Barry; W M Fairbank; D C Harrison; K L Lehrman; J A Malmivuo; J P Wikswo
Journal:  Science       Date:  1977-12-16       Impact factor: 47.728

10.  Validation of magnetocardiography versus fractional flow reserve for detection of coronary artery disease.

Authors:  Jai-Wun Park; Eun-Seok Shin; Soe Hee Ann; Martin Gödde; Lea Song-I Park; Johannes Brachmann; Silvia Vidal-Lopez; Jan Wierzbinski; Yat-Yin Lam; Friedrich Jung
Journal:  Clin Hemorheol Microcirc       Date:  2015       Impact factor: 2.375

View more
  1 in total

1.  Tunnel Magnetoresistance Sensor with AC Modulation and Impedance Compensation for Ultra-Weak Magnetic Field Measurement.

Authors:  Wenlei Zhao; Xinchen Tao; Chaofeng Ye; Yu Tao
Journal:  Sensors (Basel)       Date:  2022-01-28       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.