Determination of cardiac output by single gated pulsed Doppler echocardiography.

J H Fast1, L van den Merkhof, W Blans, K van Leeuwen, G Uijen.   

Abstract

The aim of the study was to evaluate the use of single gated pulsed Doppler cross-sectional echocardiography for measurement of the cardiac output. Pulsed Doppler echocardiography was used to assess both area and blood velocity at the aortic orifice. Stroke volume estimates were determined by multiplying area by systolic time velocity integral as measured from the parasternal and apical approach, respectively. We investigated a group of 17 healthy individuals and a group of 20 patients with coronary artery disease. In the first group no change was found in aortic area during systole (P less than 0.01). During a follow-up of two weeks no change in aortic area was observed either (P less than 0.01). Intraobserver, interobserver and day-to-day variability of the aortic area, expressed as the coefficient of variation was 3.6 +- 5.2%, 4.6 +- 5.7% and 7.8 +- 3.8% (mean +- 1 SD), respectively. The interobserver variability of the time velocity integrals was 6.0 +- 6.2%. In the second group the cardiac output as measured with the thermodilution method ranged from 3.8 to 8.0 l/min. Comparison of the Doppler and thermodilution technique for measurement of cardiac output showed a correlation coefficient of r = 0.76 (P less than 0.001) and the following regression equation: CO (Doppler) = 1.0 x CO (thermodilution)-700 ml. The Doppler method underestimated cardiac output relative to the thermodilution method.

Entities:  

Mesh:

Year:  1988        PMID: 3220601     DOI: 10.1016/0167-5273(88)90006-x

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  3 in total

1.  Improved method for cardiac output determination in man using ultrasound Doppler technique.

Authors:  M Eriksen; L Walløe
Journal:  Med Biol Eng Comput       Date:  1990-11       Impact factor: 2.602

2.  Reference values of aortic flow velocity integral in 1193 healthy infants, children, and adolescents to quickly estimate cardiac stroke volume.

Authors:  Christiane Pees; Eva Glagau; Jakob Hauser; Ina Michel-Behnke
Journal:  Pediatr Cardiol       Date:  2013-01-24       Impact factor: 1.655

3.  Impact of left ventricular outflow tract ellipticity on the grading of aortic stenosis in patients with normal ejection fraction.

Authors:  Frédéric Maes; Sophie Pierard; Christophe de Meester; Jamila Boulif; Mihaela Amzulescu; David Vancraeynest; Anne-Catherine Pouleur; Agnès Pasquet; Bernhard Gerber; Jean-Louis Vanoverschelde
Journal:  J Cardiovasc Magn Reson       Date:  2017-03-15       Impact factor: 5.364

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.